association with surrounding ecosystems. ISSUES: Often contains obligate seed regenerating species and as

such, the application of frequent fire may reduce species richness if the intervals between fire are not
sufficient for plants to produce seed. Too frequent a fire frequency may result in a net loss of nutrients over
time from an already nutrient poor system. Spring burns (traditionally used in SEQ ecosystems) have an
associated risk due to changing weather conditions post-burn. The fire interval recommendation provides a
guide to burning frequency and should be adjusted according to the ’reading of country’ and observed
ecosystem health in relation to fire.



4.1        Fire History and Frequency




                              ..,"                                                     ..
                                     ;::;




Figure 8. Evidence of previous fire.

Evidence of previous fire in the area (at least 15 20 years ago) can be seen throughout the area in various
                                                          -




forms, however the last fire in the area was many years ago, judging from the:

      1.   Lichen development on old charred stumps.
      2.   Wound healing around the bases of B.aemula.
      3.   High level of fuel now accumulated.
      4.   More than one generation of Allocasuarina littoralis. With upright dead material yet to be burnt

           (Lunt,1998).

This evidence suggests fire at least 15       -
                                                 20 years ago or more, which is beyond the upper end of the

desirable fire interval for this vegetation community.

Report compiled by Bushfire Risk Reducers for Fulton Trotter Architects, April 2013             Page 13

Used in these records

About this file

File size
76.1 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Development Application Part 2 of 2 - Application Plans, Bushfire Management Plan and Fire and Evac Plan - OPW13_0463.pdf · 76.1 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.