The vegetation community clearly has an ecological need for fire, for conservation reasons. Safety considerations would also advocate the use offire in prescribed hazard-reduction burns. However the limited size of the area, absence of clear fire lines around the entire perimeter and other (higher)priorities for Council parks resources are likely to prevent routine controlled burns. The next fire is therefore likely to be an unplanned fire, with potential intensity dependant on prevailing fire weather conditions at the time. 5.0 Specific risk factors associated with the development proposal 5.1 Nature of activities anticipated on site The Noosa Plan requires Education Type 4 uses to function effectively during and immediately after bushfire events. In NSW such developments are treated as Special Fire Protection Purpose Developments and an elevated level of bushfire planning and design is specifically applied. Whilst Queensland planning requirements are less specific in this regard, it is suggested that Planning for bushfire protection (NSW RFS, 2006) provides appropriate guidance for planners. This includes such specific measures as radiant heat levels not to be experienced above 10kW/m2 by emergency services workers during worst case scenarios, and additional emphasis being placed on Asset Protection Zones, Fuel Monitoring and Management Programs, and Emergency Management. The Noosa FLC buildings include an administration/support facility and dining facility with covered deck, separate buildings devoted to sound, creating, knowledge, and quiet retreat, with a separate amenities building. No storage or handling of hazardous materials in bulk is envisaged. 5.2 Numbers of people likely to be present The proposed Noosa FLC will provide education facilities for approximately 80 pupils and 10 staff. During the daytime (when wildfire outbreaks are most likely) approximately 90 people may be expected to be at the complex, a substantially smaller number than associated with most standard schools. This translates to relatively greater ease of evacuation if and when required. Report compiled by Bushfire Risk Reducers for Fulton Trotter Architects, April 2013 Page 14
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Development Application Part 2 of 2 - Application Plans, Bushfire Management Plan and Fire and Evac Plan - OPW13/0463Related documentApplication case desk ↗
About this file
- File size
- 76.1 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.