Ignition of bu dlng.
by burning embers
and debrl. ...rrl.d by
the wind
Ignition 01 buildings
by h.at radlltlon
from thl fire
Ignitlon of bu dlngs by
dirtct tt.me contact
I,
Figure 11. Main Bushfire Attack mechanisms (Image courtesy of Ramsay & Rudolf, 2003)
6.3 Anticipated severity of bushfire attack
The fuel accumulation values used in this assessment are derived from the estimated values from Section 3
of this report. These values can be less than those attributed to "forest" in AS3959-2009.
Fire Scenario -
East FDI40 Method 1 AS39S9 -
ZOO9 FDI40
Method Z AS39S9-ZOO9 Scrub
Scrub @1S/ZOt/ha.Au Slope under vegetation Flat Flat
Flame width 30m.ROS over-ridden to SO% of maximum.
Fire Intensity (Byram,1959)
15500kW/m
Rate of Spread (Noble et ai, 1980)
2kph
Flame Height (modified Mc Arthur V equation, NSW RFS
2001) 6.56m
Flame Width 30m
Elevation of Receiver 2.4m
Radiant Heat generated BAL FZ within <10m of intact unmanaged
(View Factor Method see
-
graph below) vegetation
BAL 40 from 10 -
<13m
BAL 29 from 13 -
<19m
BAL 19 from 19 -
<27m
BAL 12.5 from 27 -
<100m
Table 3. Calculated values for potential bushfire characteristics, and methods used.
Report compiled by Bushfire Risk Reducers for Fulton Trotter Architects, April 2013 Page 17
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Development Application Part 2 of 2 - Application Plans, Bushfire Management Plan and Fire and Evac Plan - OPW13/0463Related documentApplication case desk ↗
About this file
- File size
- 76.1 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.