Potential Radiant Heat Flux
80
70
60
SO
1 Scrub Frat fDI40
N
E:
......
$ 40 limit-of BAl-40 Construction AS 3959-2DD9
x
lL
:x:.
a:: 30
20
_ _ _ _ _ _ ~ _ _ _ _ _ _ _ _ _
limitofBAL-12.5Construction
10
.0
45/:, ’]5
o 20 30 40 50 ,60
1!1 i
D stanoe from unmanagedvegetation,(metres)
t i Amenity
!
Knowledge I Create
!
Retreat
-"
Figure 12. Potential Radiant Heat Flux. (Source:View Factor Model, AS3959-2009)
Figure 12 is from fire modelled (estimated)calculations, based on fire weather conditions equivalent to a
Fire Danger Index of 40, and depicts a scenario where fuels have accumulated to their likely demonstrated
potential extent. The significance of these radiant heat flux levels is shown below in Table 4.
Figure 12 shows that site specific modelling (Method 2) has predicted significantly lower BAL values for the
buildings on this site than under Method 1 of AS3959-2009. A proposed non combustible radiant heat
barrier to a minimum 1.8m further reduces radiant heat exposure (green curve in Figure 12).
Based on the available setback, if AS3959-2009 was to be applied to these (Class 9b) buildings, the exposed
faces ofthe:
. Knowledge building would require BAL 40 construction.
. Retreat and Create buildings would require BAL 29 construction.
. Amenity building would require BAL 19 construction.
. Other buildings would require BAL 12.5 construction.
. (the shielded faces of buildings would be constructed to one BAL level lower, with the
exception of BAL 12.5 buildings, the whole of which should be constructed to BAL 12.5).
The 10kW/m2limit used in NSW for Special Fire Protection Purpose developments, can only be guaranteed
in areas more than 12.5m from intact vegetation, but so long as landscaping and construction on the
subject site do not lead to ignition on the site itself, most ofthe site would fall below 10kW/m2 radiant heat
exposure.
Report compiled by Bushfire Risk Reducers for Fulton Trotter Architects, April 2013 Page 18
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Development Application Part 2 of 2 - Application Plans, Bushfire Management Plan and Fire and Evac Plan - OPW13/0463Related documentApplication case desk ↗
About this file
- File size
- 76.1 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.