7.2 Asset Protection Zones and Landscaping
Components of an Asset Protection Zone hazard
Inner protection area
~ I
Figure 14. Components of an Asset Protection Zone (APZ)
Asset protection zones are the most strategically valuable defence against radiant heat and flame, and to a
lesser extent embers.
The landscaping plan shall include the establishment and maintenance of an "Inner Protection Area" (IPA)of
a minimum of 10m out from any buildings, and maintained free of available fuel. Some landscaping plants
may be used in this area so long as they are selected for their low combustibility, by virtue of high moisture
content, low volatile oil content, high leaf mineral levels, large fleshy leaves, absence of shedding bark. They
should be placed so as to not provide either vertical or horizontal connectedness of plant material, or
contact with flammable parts of buildings.
An Outer Protection Area involves removal of the understorey so as to deprive an advancing firefront of its
fuel continuity, and thereby collapsing the fire front. In this case, we are recommending that the entire
subject lot is managed as an IPA.
The retention of plants identified in Drawings Number 12-186 LP-01 and LP-02 of the Vegetation
Management Plan (required by Council under Decision Notice MCU 12/0133) potentially risk creation of fuel
pockets close to flammable structures and parts of buildings. In order to mitigate this risk, it is
recommended that:
1. Non combustible mulches are used in landscaping.
2. Where native vegetative species are used, they should be selected from Appendix 1 (Native plants
of lesser combustibility) and be of species/ age that will rapidly reach around 3m in height, which
can be hedge trimmed, with dense foliage. Acmena spp and Syzigium spp provide a range of good
options. They serve to separate retained natives, and dampen or subdue potential fire behaviour.
3. Leaf litter should not be allowed to accumulate at ground level, and should be raked up from
gardens/under boardwalks and buildings and should be removed from site, particularly during the
fire season (August to February).
Radiant heat barriers (either man such as non combustible/colorbond or of low combustibility/fire
retardant vegetation) should be incorporated into APZ design as shown in Figure 15, to further reduce
exposure of buildings to radiant heat. Vegetative barriers can potentially become involved in fire if they are
permitted to dry out, and a key requirement (if the vegetative option is used) is to ensure that vegetation is
well watered and not suffering moisture stress, particularly throughout the fire season. The non
combustible option is recommended.
Report compiled by Bushfire Risk Reducers for Fulton Trotter Architects, April 2013 Page 21
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Development Application Part 2 of 2 - Application Plans, Bushfire Management Plan and Fire and Evac Plan - OPW13/0463Related documentApplication case desk ↗
About this file
- File size
- 76.1 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.