Council archive · source document
Development Application Part 2 of 2 - Application Plans, Bushfire Management Plan and Fire and Evac Plan - OPW13/0463
Plans and drawings: the text below has words only, no drawings.
Very large file (76.1 MB): may take a few minutes to open.
N32 CONCRETE 300
PAVEMENT
I
50mm COVER LAYER LOOSE
- N32 CONCRETE
IPAVEMENT
0(;)
:il 5-10mm CLEAN WASHED GRAVEL
, I
~
150mm GEOWEB LAYER -
TO BE LAID IN
LOT BOUNDARY
~ ~ f-
J ~j
SERVICES TO BE LOCATED AND ACCORDANCE WITH MANUFACTURES GUIDELINES
DEPTH CONFIRMED PRIOR TO COMMENCING AND FILLED WITH 5-10mm CLEAN WASHED GRAVEL
WORKS.MIN 600mm COVER REQUIRED-
TENSAR GEO-GRID TriA)( TX 140
..
SERVICES TO BE RELOCATED TO CORRECT
COVER IF REQUIRED OR PROTECTION
DETAIL AGREED WITH UTILITY OWNER
SUBGRADE TO BE COMPACTED
TO ACHIEVE A MINIMUM DENSITY
NOTE:
NO GEOFABRIC TO BE USED IN
SUBGRADE TO BE COMPACTED TO
j
.<1 100mm TRANSITION LAYER -
1-2mm ACHIEVE A MINIMUM DENSITY
<1 INDEX OF 75%(AS1289.5.6.1). PERMEABLE PAVEMENT CONSTRUCTION
. CLEAN WASHED WELL GRADED SAND INDEX OF 75% (AS1289.5.6.1).
(NO FINES) D15<lmm DB5>2mm
TYPICAL CONCRETE CARPARK TYPICAL CARPARK PERMEABLE TYPICAL CONCRETE FOOTPATH DETAIL
AND EDGING DETAIL PAVEMENT DETAIL SCALE 1:10
SCALE 1:10 SCALE 1:10
R16 DOWELS SAWCUT 400 LG AT
EXISTING 400 CRS GREASE ONE END STOP NOTE
EXISTING FOOTPATH TO BE RETAINED
TO BE RETAINED
~ BARS 600MM FROM JOINT
INTERSECTIONS STOP REINFORCEMENT 25
THIS PAVEMENT HAS BEEN DESIGNED TO
MEET SUNSHINE COAST REGIONAL COUNCIL
CLEAR OF JOINT
LOCAL ROAD DESIGN SPECIFICATION -
THE
ESA’S FOR A LOCAL ROAD IS 5.0X 10’.
<1 _
Ll
-d 4
Ll.
2 N16 CONTINUOUS SUPPORT BARS ON
<1 Ll CHAIRS AND DISCS BARS NOT
CONTINUOUS THROUGH JOINT
<1
INTERSECTIONS
c
<1
PARCHEM FOSROC "ROADSEAL"OR
TYPICAL DOWELLED JOINT DETAIL (OJ1)
~ APPROVED EQUIV
Ll<1 . SCALE 1:10
Ll <1
ENSURE MIN 600mm CLEARANCE BEHIND -
<1
PARCHEM FOSROC "EXPANDAFOAM ROD"
KERB FOR VEHICLE OVERHANG
<1 OR SIMILAR
EXISTING MOUNTABLE KERB AND ,WHEELSTOP TO BE SECURELY ATTACHEDTO
CHANNEL TO BE CUT AND TYPE B IPWEAQ TYPE ER2 -
CONCRETE SLAB IN ACCORDANCE WITH
< PLANTING IN THIS AREA TO BE -
MOUNTABLE CROSSOVER CONSTRUCTED IN 1 REINFORCEMENT TO IPWEAQ MANUFACTURERS SPECIFICATION AN D
LOW LEVEL PLANTING -
REFER
KERB AND CHANNEL ACCORDANCE WITH STD DWG Ll <1 STD. DRG No. R-0080 GUIDELINES -
ENSURE OPENINGS BETWEEN
Ll. LANDSCAPE ARCHITECT
TO BE MAINTAINED IPWEAQ R-0051 -
EXISTING SUBSOIL WHEELSTOPS TO ALLOW OVERLAND FLOW CUT EVERY 2ND CROSS BAR
DRAWINGS FOR DETAILS
DRAINAGE TO BE MAINTAINED 25 CLEAR OF JOINT
:<1 ACCESS ROAD 230 CARPARK
Ll
. I 150
---:----
Ll<i
-~<r
--
1\
,
I :ilj I~
300
iSL72 MESH
/
---~ --,..,L~
NOTE: DEPRESS MESH LOCALLY TO
\,’ ~Ltl MAINTAIN COVER
@ GIRRAWEEN COURT
r--~---
, , 1’:l
" -...___ -
CROSSOVER DETAIL
~ I~ -
600
SUBGRADE TO BE COMPACTED
TYPICAL SAWN JOINT
SCALE 1:10
(SJ1)
150mm C8R45 TYPE 2.3
SCALE 1:50 380
TO ACHIEVE A MINIMUM DENSITY NOTE:
COMPACTED TO 98% STD MDD
INDEX OF 75% (AS1289.5.6.1). ~TTO BE AIR BLASTED PRIOR TO APPLICATION OF SEALANT.
REFER TO MANUFACTURERS SPECIFICATION FOR EARLIEST
BARRIER KERB TO EDGE OF KERB TO FRONT OF CUTTING TIME.
2. JOINTS TO BE PROVIDED AT A MIN AS FOLLOWS
PERMEABLE PAVEMENT CARPARKING BAYS DETAIL 2.1. SAWN JOINTS AT 3m MAX CENTRES
SCALE 1:10 SCALE 1:10 2.2. DOWEL JOINTS AT 12m MAX CENTRES
SECTION H
SCALE 1:20 (Al)
!
31.5
EXISTING KERB TO
tOm
MAX 1 IN 8
3.0m
MAX 1 IN 40 (VARIES) 2.03m (VARIES)
FOOTPATH TO MATCH EXISTING
FOOTPATH WIDTH AND CROSSFALL
""’"-’~
BE?fS
CUT AND REMOVED
~
~
.1
l
31
30.5
GIRRAWEEN COURT
./"
----
-
-=~t
I 30
---------------------------
~
f SECTION NOTE
SCALE 1:20 (Al) tTHiS DRAWING TO BE READ IN CONJUNCTION
WITH STANDARD NOTES ON COOl
I NOT FOR CONSTRUCTION 2. THIS DRAWING TO BE READ IN CONJUNCTION
WITH ALL OTHER CONSULTANTS DRAWINGS
SCALE 1.50
SCALE ,.,0 01
10
02 03
2.Om
04m
I
~
r=- BLIGH TANNER
... CONSULTING ENGINEERS
REV
A
B
C
D
DATE
25-09-2012
25-03-2013
17-05-2013
13-06-2013
DESCRIPTION
PRELIMINARY
FOR INFORMATION
FOR REVIEW
OPERATIONAL WORKS
OES~
PS
PS
PS
PS
ORA\\!<
PS
PS
PS
PS
CHECKED
AH
CR
CR
APPROW
CR
CR
RPEO PROJECT
LOCATION
2 GIRRAWEEN COURT, SUNSHINE BEACH, QLD
NOOSA FLC DRAWNGTITLE
ARCHITECT
ROADWORKS DETAILS SCAlES
Joe NO
AS SHOWN
FULTON TRODER 2012.164.200
~ LEVEL 9, 269 WICKHAM STREET, PO BOX 612
~ FORTITUDE VALLEY aLD 4006 AUSTRALIA CLIENT ASSOCIATE CONSULTANT ORAWNGNO REVISION
I T 07 3251 8555 F 07 3251 8599 FULTON TRODER
C302 D
ALL RIGHTS RESERVED. THIS WORK IS COPYRIGHT AND CANNOT BE REPRODUCED IN ANY FORM OR BY ANY MEANS (GRAPHIC,ELECTRICAL OR MECHANICAL, INCLUDING PHOTOCOPYING)WITHOUT THE WRITTEN PERMISSION OF BLIGH TANNER. ANY LICENCE, EXPRESS OR IMPLIED, TO USE THIS OOCUMENT FOR ANY PURPOSE WHATSOEVER IS RESTRICTED TO THE TERMS OF AGREEMENT OR IMPLIED AGREEMENT BETWEEN BLIGH TANNER AND THE INSTRUCTING PARTY
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Development Application Part 2 of 2 - Application Plans, Bushfire Management Plan and Fire and Evac Plan - OPW13/0463Related documentApplication case desk ↗
About this file
- File size
- 76.1 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.