           and disposal system                 water supply, the premises is     A 45,000 litre and additional
           that does not have                  serviced with a rainwater tank    5,000 litre rainwater tank will be
           an adverse effect on                with the following minimum        connected to the dwelling for
           ecologically                                                          general and fire fighting
                                               water supply capacity:
                                                                                 purposes. (5kL to be dedicated
           important areas or
                                               (a)   for dwellings with no       to fire fighting purposes)
           water quality; and                        more than 3 bedrooms –
      c.   adequate onsite water                     45,000 litres; or
           storage to support the
           efficient use of water              (b)   for dwellings of more
           and is adequate for                       than 3 bedrooms or
           everyday use of the                       where including a
           occupants.                                secondary dwelling on
                                                     the same premises –
                                                     60,000 litres.


                                       AO5.3   If located on a lot where          See effluent disposal report
                                               reticulated sewerage is not
                                               available to the lot, the dwelling
                                               is connected to an on­site
                                               effluent treatment and disposal
                                               system.
PO6   Landscaping:                     PO6     Soft landscaping is provided        Existing vegetation will be
                                               and retained to a minimum of        retained outside the building
                                                                                   area which will account for
      Buildings and structures                 20% of the site area.
                                                                                   approximately 80% of the site
      allow for sufficient space for                                               cover.
      outdoor activities, garden
      areas and screening to
      surrounding land uses.
PO7   Car Parking:                     AO7     Car parking is provided in        Car parking has bee provided in
                                               accordance with Table             accordance with table 9.4.1.4 of
                                                                                 the driveways and parking
      Sufficient car parking is                9.4.1.4 of the Driveways and
                                                                                 code.
      provided to accommodate                  parking code.
      the number of vehicles likely
      to use the site.
PO8   Access Design:                   AO8.1   Driveways and crossovers          The driveway will be
                                               are designed to comply with       constructed to comply with
                                                                                 Council’s prescribed standards.
      The design, management                   Council's standard drawings
      and maintenance of the                   RS­049, RS­050, RS­056 and
      access facilitates:                      addendum as applicable.
      safe and convenient use for
      vehicles, pedestrians and        AO8.2   Where a footpath exists, the
      cyclists;                                                                  N/A
                                               driveway meets the road
      vehicles negotiating                     reserve at the level of the
      without contacting the                   existing footpath.
      driveway or crossover
      surface; and                     AO8.3
                                               Driveways within the property:
                                                                                 The driveway will be
      stormwater disposal without
                                               (a)   have a maximum              constructed to comply with
      any negative impacts on the
                                                     gradient of 20% and         Council’s prescribed standards.
      surrounding area.
                                                     vertical curves to
                                                     ensure no scraping
                                                     for a standard
                                                     vehicle; or
                                               (b)   have a maximum gradient
                                                     of 25% provided–
                                                      (i)    the length of
                                                             the driveway
                                                                                                   19 | P a g e
Log in to download the original file

Planning Report.pdf · 647 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.