Original source · versioned page text
2017-02-13 General Committee Meeting Notes
Text sections have not been matched to the original PDF pages. Use the original document to check page numbers.
RECOMMENDATIONS ONLY – NOT THE FINAL DECISION OF COUNCIL
GENERAL COMMITTEE MEETING 13 FEBRUARY 2017
h. Roof/ceiling of areas where amplified entertainment is proposed should be
constructed to achieve a minimum Rw rating of 50.
i. At the time of installation, new mechanical plant and equipment, a/c units,
motors, refrigeration equipment, compressors, pumps etc associated with Stage
4 of the development, should be installed within the building or suitably provided
with noise reduction measures and located as to prevent a noise nuisance
beyond the boundary of the site and not exceed the levels specified in Table 1.
TABLE 1
NOISE LIMITS AT A SENSITIVE RECEPTOR
Noise level at noise sensitive place measured as the adjusted
PERIOD
maximum sound pressure level (L10, adj,T)
7am – 6pm Background noise level (L90,T) plus 5 dB(A)
6pm – 10pm Background noise level plus 5 dB(A)
10pm – 7am Background noise level plus 3 dB(A)
NOISE LIMITS AT A COMMERCIAL PLACE
Noise level at a commercial place measured as the adjusted
PERIOD
maximum sound pressure level (L10, adj,T)
7am – 6pm Background noise level (L90,T) plus 10 dB(A)
6pm – 10pm Background noise level plus10 dB(A)
10pm – 7am Background noise level plus 8 dB(A)
Acoustic Report
2021. An acoustic report prepared by a suitably qualified person* is to be submitted to
Council confirming assessment and certification of measured noise levels from the new
mechanical plant and equipment, a/c units, motors, refrigeration equipment,
compressors, pumps etc comply with the noise limits as set out in Table 1 and all other
relevant noise conditions of this Decision Notice associated with Stage 4 of the
development.
2122. The report is to be submitted after commissioning any new equipment (with all plant
and equipment operating at the same time) and when all building extensions are
complete.
2223. Measurement of sound pressure levels (adjusted for tonality and impulse) must be in
accordance with Australian Standard AS1055.1 “Acoustics – Description and
measurement of environmental noise – General procedures”.
Suitably Qualified Person* - Certification
For the purpose of measuring and certifying compliance with relevant noise conditions
of this Decision Notice, a suitably qualified person is either:
i. a Registered Professional Engineer of Queensland, or
ii. an environmental consultant with a minimum of three (3) years current
experience in the field of acoustics.
Outdoor Lighting Devices
2324. Lighting associated with the use must be designed, sited, installed and tested to
comply with Table 2.1 & 2.2 of Australian Standard AS4282-1997 “Control of the
obtrusive effects of outdoor lighting” using a control level of 1 and not cause a nuisance
to the adjacent residential areas.