Council archive · source document
Delegated Report - Code - Planning MCU26 0001 - AS PUBLISHED · MCU26/0001
Performance Bond
8. Security in the form of a cash bond or trading bank guarantee to the sum of $20,000 must
be submitted to Council, to secure performance of all conditions of this approval, prior to the
pre-start meeting. The cash bond or trading bank guarantee will be returned on performance
of the conditions of approval less any costs incurred by Council in respect of enforcing
performance of this permit. Council reserves the right to call upon the bond or guaranteed
sum to effect compliance with conditions.
Street Identification
9. The street address of the development must be clearly visible and discernible from the
primary frontage of the site by the provision of a street number and, where appropriate, the
building name.
Building Appearance
10. External design features, materials and finishes must be as shown on the Approved Plans
(refer to approved Materials and Finishes Palette), with no inclusions or alterations made
without approval in writing by Council.
11. External finishes of the building must be a mix of lightweight and textured external finishes,
with masonry areas incorporating a variety of textured finishes to break up the surface.
12. All deck and balcony areas must not be enclosed with shutters, louvres, glass panelling or
the like thus remaining as open structures, except where required to satisfy any privacy
condition of this Decision Notice.
13. Waste storage areas, clothes drying areas and external storage areas must be screened
from view of the street.
Fencing and Walls
14. Any street fencing must not exceed 1.8 metres in height, be set back an average of 1 metre
and articulated to provide visual interest by stepping the design. Any fencing on the front
boundary must either:
a. not exceed a maximum height of 1.2 metres
b. be of open construction.
15. The area of land between the fence and the front property boundary must be densely
landscaped to screen any fencing from the street.
Protection of Privacy
16. The upper-level balconies located on the northern and southern elevations of the building
must include either balcony planter boxes, non-transparent balustrading, positioned in such
a way to obscure direct views into the habitable room windows or private open space areas
of the adjoining property.
Waste Management
17. A waste storage area must be designed and maintained in accordance with Planning
Scheme Policy PSP9 Waste Management and the Noosa Plan’s Waste Management Code.
The waste storage area must be:
a. imperviously paved and correctly sized for all refuse and recycling containers;
b. bunded and graded so that wastewater and bin leakage drain to the sewer;
c. provided with a conveniently located hosecock and backflow prevention device,
connected to a water supply to service the area; and
d. roofed or otherwise covered.
Page 19 of 33
Document Set ID: 24436845
Version: 6, Version Date: 09/09/2026
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Delegated Report - Code - Planning MCU26 0001 - AS PUBLISHEDRelated documentApplication case desk ↗
About this file
- File size
- 8.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file