Council archive · source document
Minor Change Existing Approval MCU19/0149 02 (AS PUBLISHED) · MCU19/0149.02
23. The installation and/or modification of any traffic signs, street signs, line marking and Raised
Reflective Pavement Markings (RRPMs) must be in accordance with the Manual of Uniform
Traffic Control Devices (MUTCD). New or relocated signage must be installed using the VLok
installation system. All new signage must be Class 1 retroreflective material in accordance
with AS 1906.1, Retroreflective materials and devices for road traffic control purposes – Part
1: Retroreflective sheeting.
24. All operational works for external works, landscaping and fixtures within the State controlled
road reserve must obtain written approval from the Department of Transport and Main Roads
prior to the commencement of works.
Road Reserve Dedication
25. Dedication of road reserve must be provided to accommodate the proposed public pathway.
The north western corner of the lot is to be truncated (2 metres along each frontage at a 45
degree angle). The road dedication must be finalised prior to the commencement of the use.
Site Access and Driveways
26. A sealed access driveway must be provided from Pearl Street to all parking and manoeuvring
areas of the development. The works must be undertaken in accordance with an Operational
Works approval and generally in compliance with the approved plans, and must include in
particular:
a. A driveway crossover generally in accordance with SEQ R-051, Type A.
b. A driveway maximum width of 7.0 metres at the kerb line unless approved otherwise
by Council.
c. Driveway edges and layback must not encroach onto the prolongation of the property
side boundary at the kerb line.
d. Any required alteration to existing drainage system due to the proposed driveway.
e. Conduits for underground service for utility services.
Car Parking
27. In addition to the proposed on-street car parking spaces, a minimum of 10 car parking and 4
motorcycle parking spaces must be provided and marked on-site, and made available and
accessible at all times while the use is open for business. The works must be undertaken
generally in accordance with the approved plans and in compliance with an Operational
Works approval and must include in particular:
a. One (1) disabled parking space/s within the total
b. Pedestrian routes/connections between the parking area and the shops at the rear.
c. Provision of vandal resistant public lighting with intensities to satisfy the requirements
of Australian Standard AS1158: Public Lighting Code
d. Dimensions, crossfalls and gradients in accordance with Australian Standard AS2890:
Parking Facilities.
e. Details of all required line marking and parking and traffic signs.
28. All car parking areas and access driveways must be maintained exclusively for vehicle
parking and manoeuvring and kept in a tidy and safe condition at all times.
Public Pedestrian Pathway
29. A pedestrian pathway must be provided for the development, a minimum of 2 metres in width,
along the full length of the Elm Street and Pearl Street property frontages. The works must
be undertaken in compliance with an Operational Works approval and must include in
particular:
a. Concrete footpath/s within the road reserve for the entire length of the site’s frontages
to the public roads.
Page 5 of 11
Document Set ID: 23199036
Version: 3, Version Date: 16/08/2024
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Minor Change Existing Approval MCU19/0149 02 (AS PUBLISHED)Related documentApplication case desk ↗
About this file
- File size
- 183 KB (small file)
- File type
No other editions are linked here.