Residential Use Code – Table 14‐24 For All Residential Uses
RESIDENTIAL USE CODE
Specific Outcome Probable solutions (if code assessment) Complies Comments
14.46 Effects of use
Electricity supply infrastructure
O1 The development does not adversely impact on existing or future S1.1 No solution provided N/A 01, S2.1‐2.3 Not applicable. The
electricity supply infrastructure; S2.1 Development for uses adjacent to or within 50m of an existing development is not situated near high
AND electricity substation incorporates noise attenuation measures to mitigate voltage powerlines or overhead electricity.
O2 All uses and works maintain an adequate safe distance from electrical noise impacts;
infrastructure including substations, overhead powerlines, power poles AND
and transformers. S2.2 Buildings and structures (including swimming pools, sheds, tennis courts
or outbuildings) are not constructed under overhead electricity transmission
lines, or within electricity easements;
AND
S2.3 A minimum separation distance is maintained from the electricity
transmission line to the closest boundary of habitable buildings and child
activity areas, as follows—
a) 20m for transmission lines up to 132kV;
b) 30m for transmission lines between 133kV and 275kV; and
c) 40m for transmission lines greater than 275kV.
Water supply and conservation
O3 On‐site water storage is designed and operated to support the S3.1 & S4.1 For a Class 1 building18 other than a Detached house, outside a N/A S3.1‐4.1 Not applicable. The development
efficient use of water; reticulated water service area, a rainwater tank is to be installed with the is connected to reticulated water supply.
following minimum storage capacities—
AND a) Where no more than 3 bedrooms – 45,000 litres; or
O4 On‐site water storage is adequate for occupants every day use and b) Where more than 3 bedrooms – 60,000 litres;
fire fighting purposes.
AND
c) There is to be on the lot a dam, swimming pool or water tank accessible
for use by the fire brigade that contains at least 5,000 litres of water.
Editor’s note: The 5,000 litres required can be included within the water
required in S3.1 or S4.1 providing it is accessible for the purpose of fire
fighting at all times and not used for other domestic purposes.
Mixed Use Developments
O45 Where the multiple dwelling units form part of a mixed use
development, the development provides residents with reasonable
S45.1 Entry areas for the residents of, and visitors to, dwellings units are
provided separately from entrances for other building users and provide for
S45.1 – S45.3 Complies. The minor change
is for a minor ancillary aspect and will
privacy and security. safe entry from streets, car parking areas and servicing areas. provide reasonable privacy and security.
JFP Ref: M2652/E2 Page 26