14169-001-Rev0 17 Webb Rd -Revised Draft · 132002.220527.1
Attached to the e-mail 132002.220527.1 Change to Existing Approval Engineering & Geo tech reports (1of 6 emails).
17 WEBB ROAD, SUNSHINE BEACH PROPOSED RESIDENCE 7.0 ENGINEERING ASSESSMENT 7.1 Earthworks It is assumed that cut and fill up to about 1.5 m BGL may be required to form the ground level building pad. 7.1.1 Site Preparation and Trafficability Following removal of sections of the existing building, and clearing of vegetation and any unrequired below ground elements (e.g. services), tree stumps and large roots must be ‘grubbed out’ and any organic rich topsoil stripped from the construction area. Topsoil materials must not be used in structural fill, however may be placed across landscaping areas. The subgrade materials exposed after site stripping and excavation to design levels (up to 1.5 m BGL) are expected to medium dense sands and silty sands. The soils would be subject to strength loss from repetitive vehicle loading (particularly from rubber tyred plant). Due to the potential for poor trafficability, placement of a minimum 150 mm thick granular working platform may be required to create a ‘confining’ layer to prevent loosening of the sand, particularly across access and laydown areas. The site should be graded to shed surface water runoff away from construction areas. Swale drains should be constructed along the toes of any cuts, and above cuts where possible, with the drains graded to discharge collected waters to a control point before release off-site. 7.1.2 Excavations T Excavations to depths of up to 1.5 m BGL in the mostly loose to medium dense sands should be achievable using conventional earthmoving plant (e.g. small to medium excavators) with toothed bucket attachments. AF Temporary cuts in loose to medium dense sand and batters in controlled fill may be formed no steeper than 1V:1H. Any permanent batter slopes in such materials should be formed at 1V:2H, or flatter if possible (1V:3H). Flatter batters may be required if groundwater seepage is encountered, or if earthworks are undertaken during a period of heavy rainfall. Any excavations required adjacent to existing structures, including those on adjoining properties, will need to R be specifically designed to ensure that the structures are not adversely affected (e.g. 'undermined'). The above recommendations do not supersede any existing safety regulations or legislation applicable to D excavations (e.g. limits on personnel entry into trenches). 7.1.3 Filling Should any importation of fill be required, the use of low reactivity materials (plasticity index less than 15%) is recommended for any fill under the building. All structural fill should be compacted at moisture contents within the range of ±2% of optimum moisture content for Standard Compaction. Fill should be placed in 250 mm thick (loose thickness) layers and be compacted by repeated rolling to achieve a dry density ratio of at least 95% of the maximum Dry Density Ratio (DDR), based upon the Standard Compaction method, or 70% Dry Density Index. To compact sand fill it is normally necessary to place the loose fill layer, flood the area with water and compact with a vibratory smooth drum roller. Care will need to be taken with the addition of water if the sands are particularly silty. Confirmatory compaction testing must be carried out at regular intervals. A minimum of two tests per vertical lift is recommended where structural fill heights are to exceed 300 mm. Further details for control and testing of fill are given in Australian Standard AS 3798-2007 Guidelines on Earthworks for Commercial and Residential Developments. Fill must be ‘benched’ into the natural slope, over-filled by 0.5 m (horizontally) and then trimmed back to the well compacted material. Due to the close proximity of houses on adjoining properties, care will need to be taken within any activities which may cause excessive ground vibrations (e.g. fill compaction). It would be prudent to conduct a 26 February 2015 Report No. 14169-001-Rev0 11
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
14169-001-Rev0 17 Webb Rd -Revised Draft.pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.