Council archive · source document
14169-001-Rev0 17 Webb Rd -Revised Draft · 132002.220527.1
Attached to the e-mail 132002.220527.1 Change to Existing Approval Engineering & Geo tech reports (1of 6 emails).
17 WEBB ROAD, SUNSHINE BEACH PROPOSED RESIDENCE dilapidation survey of nearby structures before commencement of construction, and to monitor ground vibrations during construction works. Vibration may need to be “switched off” on rollers if excessive vibrations is encountered. 7.2 Building Foundations 7.2.1 Site Classification Based on the results of the investigation, the site (existing natural soil profile) is classified as Class S in accordance with AS 2870-2011 Residential Slabs and Footings. The estimated characteristic surface movement (‘ys’) at this site is less than 20 mm. It should be noted that the predicted order of movement is based on the existing natural soil profile (i.e. no cutting or filling), and moisture content changes within soils due to normal seasonal moisture variations only. 7.2.2 Footing Design All footings supporting the proposed residence and associated retaining walls must be taken through any fill and loose sand to found at least 0.2 m into the underlying medium dense (or denser) natural sand. Based upon the results of the investigation the recommended foundation materials are likely to occur at depths of about 0.5 m BGL, or deeper where fill is proposed. High level footings such as a slab beams, pad or strip footings would be suitable to support the proposed building. Should the client wish to address the assessed low risk associated with retrogressive failure of the sand dune affecting the building in the future, it is recommended that the building could be supported on T screw-in piles taken to found in the dense to very dense natural sand at about 2.5 m BGL. These materials should remain relatively stable even if exposed to wave erosion. Such piles could be designed using an allowable end bearing capacity of 1 MPa. AF It is recommended that foundation materials should be inspected by a suitably qualified and experienced engineer to confirm founding depth and allowable bearing capacity. All footings should found such that they are not adversely affected by any adjacent excavations, batter slopes, trenches, or retaining walls that are not designed to support building loads. To minimise the potential for any R adverse interaction effects, footings should found at least below a plane extending 1 m horizontally from the base of trenches/batter slopes/excavations/retaining walls, then rising up at 1V:1H. This requirement is illustrated in Text Figure 11 below. D Text Figure 11: Footing depth to minimize risk of undermining If any soil conditions encountered during construction are found to differ from those noted in the geotechnical investigation, Tectonic should be notified immediately and an inspection carried out to determine if changes to footing design are required. 26 February 2015 Report No. 14169-001-Rev0 12
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
14169-001-Rev0 17 Webb Rd -Revised Draft.pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.