09/0951 - Approved plans [As Published] · 132009.951
Plans and drawings: the text below has words only, no drawings.
GENERAL NOTES | RPD 1. THESE DRAWINGS TO BE READ IN CONJUNCTION WITH i LOT: 90 ALL OTHER CONTRACT DOCUMENTS, INCLUDING ENGINEERING. : 2. FIGURED DIMENSIONS TO TAKE PREFERENCE OVER ) . SCALED DIMENSIONS * ( RP NO: 59216 . ALL DIMENSIONS TO BE VERIFIED ON SITE BY BUILDER . . PARISH: NOOSA PRIOR TO THE COMMENCEMENT OF WORK 4.REFER ANY DISCREPANCIES TO DESIGNER FOR WRITTEN COUNTY: .MARCH eee INSTRUCTION . BUILDING TO ENSURE CORRECT BU IG SETOUT AND . . COMPLIANCE WITH STATUTORY HEIGHT LIMITS AND i > SHI RE: SUNSHINE COAST BOUNDARY SETBACKS. ' AREA: 506 m2 6. THE STRUCTURE SHALL BE PROTECTED FROM TERMITE ATTACK IN COMPLIANCE WITH AS3660.1AND BCA 3.13. i 7, STORMWATER TO BE DISCHARGED TO COUNCIL i REGULATIONS 8. DRAINAGE WORK TO COMPLY WITH COUNCIL REGULATIONS. 9, ALL WORK TO BE IN ACCORDANCE WITH THE B.C.A. AND AS 1684.2-1999 AND ENGINEER ORAWINGS AND SPECIFICATIONS. 10, ALL DOORS TO ENCLOSED SANITARY COMPARTMENTS : TO HAVE LIFT OFF HINGES, OPEN OUTWARDS, OR BE SLIDING DOORS. UNLESS THERE IS AT LEAST 1.2m BETWEEN CLOSET PROPOSED DRIVEWAY PAN WITHIN THE SANITARY COMPARTMENT AND THE i NEAREST PART OF THE DOORWAY. . | fe _ 44, ALL WET AREAS ARE TO BE WATERPROOFED IN ACCORD. Landscape 4 BORY TO FLYOVER ROOF WITH CLAUSE 3.8.1 OF THE B.A 42. SMOKE DECTECTORS ARE REQUIRED TO BE INSTALLED IN ;CORDANCE WITH CLAUSE 3.7.2 OF THE BCA & AS 3786 Mises ARE TO BE CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH CLAUSE 3.9.2 OF THE BCA. 44, STAIRS TO BE CONSTRUCTED AND INSTALLED IN PROPOSED DWELLING [ACCORDANCE WITH CLAUSE 3.9.1 OF THE BCA. . INSTALL VENTILATION TO WATER CLOSETS (NATURAL OR Gueciioica TO COMPLY WITH CLAUSE 3.8.5 OF THE BCA. 6, SUB-FLOOR VENTILATION, 400mm CLEARANCE REQUIRED TO U/S OF BEARER IN ACCORDANCE WITH BCA PART 3.4.1 Fig. 3.4.1 Diag, b. (NOTE: EXCLUDES BUSHFIRE RISK LEVEL 1/MEDIUM AND ABOVE) 17. SITE TO BE CUT AND FILLED IN ACCORDANCE WITH GEOTECHNICAL ENGINEERS SPECIFICATIONS. ALL LEVELS TO BE CONFIRMED ON SITE PRIOR TO CONSTRUCTION. 18,EXCAVATIONS TO BE IN ACCORDANCE WITH BCA 3.1.1 AND ENGINEERS DESIGNS, DRAINAGE WORK TO COMPLY WITH GEOTECHNICAL ENGINEERS... RECOMMENDATIONS AND STRUCTURAL ENGINEERS DETAILS. 49.ALL EARTH WORKS, FOOTINGS AND SLABS TO BE IN ACCORDANCE WITH ENGINEERS DESIGN AND DETAIL. 20. DRIVEWAY AND CROSSOVER TO BE IN ACCORDANCE WITH COUNCILS STANDARD DRAWING DETAILS. 21. ANY REQUIRED RETAINING WALLS, SITE WORKS AND ' STORMWATER DRAINAGE ARE TO BE COMPLETED PRIOR TO CUPANCY, IND CLASSIFICATION - N3 e "+ ALL CONSTRUCTION TO BE CARRIED OUT IN ea - ACCORDANCE WITH AS 1684.2 FOR A WIND 5% e@ CLASSIFICATION OF N3 ge 5 URUNGA PARADE 3016 BDRY TO Pos (SETOUT POINT) <4 ‘Temporary Benchmark nail in concrete. 6499 RL 2.044m BORY TO POST wW ers'Z f* lh za r (SETOUT POINT) 51.422 m - PROPOSED DECK 2 PROPOSED DECK 1 SUNSHINE COAST REGIONAL COUNCIL Site Plan 1 I ©copyright. All plans are subject to copyright and may not be reproduced in whole or in part without the express written permission from Bush & Beach Pty. Ltd. : This building shall be constructed in accordance with the current BCA, and all retevent Australian Standards. Template V1.8 - 24.02.09 2 e04% “es Bush & Beach Pty. Ltd. - : DRAWN: _ GW. DWG No. _}ISSUE: (DETAILS: DATE:_| Draw "N" Design Pty. Ltd. nw bushancbesch.om au CLIENT: PROPOSED DWELLING TITLE: Seo A__|WORKING DRAWINGS 26/06/09! | icence soeseo8 Ph, 1300 305 350 Donna Jefferies Lot 90 Site Plan CHECKED. (WW _1982670 |B [WORKING DRAWINGS oan BSA 1144953 Urunga Pde . DATE: o2o7me | 9 - i SCALE: 1: BSA 1144953 Boreen Point, QLD, 4565 ‘ —— Sue a 18 Date: t
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
09/0951 - Approved plans [As Published]Related documentApplication case desk ↗
About this file
- File size
- 764 KB (small file)
- File type
No other editions are linked here.