NATURAL HAZARDS OVERLAY CODE e a
ro | “pmm
Performance Criteria and Acceptable Solutions ‘1 BRISBANE
PERFORMANCE CRITERIA ACCEPTABLE SOLUTIONS 10] Use) Soe COMMENTS COUNCIL USE ONLY
AND
$14.4 Works avoid any reductions in on-site flood
storage capacity and contain within the site any
adverse changes, including changes to the depth,
duration or velocity of flood waters up to and
including a 1% AEP (1:100 year ARI) flood event.
015 Development does not result in adverse | $15.1 No solution provided
impacts on people’s safety and capacity to use land
within floodplains.
Hazardous materials
016 Public safety and the environment are not | $16.1 Hazardous materials are manufactured and NIA The subject site is not within a flood hazard area.
adversely affected by the detrimental impacts of | stored above the level of a 1% AEP (1:100 year
floodwater on hazardous materials manufactured or | ARI flood event;
stored in bulk.
OR
$16.2 Buildings or structures used for the
manufacture or storage of hazardous materials are
designed to prevent the intrusion of floodwaters up
to the level of a 1% AEP (1:100 year ARI) flood
event.
Infrastructure
017 Sewerage treatment plants maintain their | $17.1 Components of the sewerage treatment NIA The subject site is not within a flood hazard area.
function during flood events up to a 1% AEP 1:100 | plants that are likely to fail or may result in
year ARI) flood event. contamination are—
a) located above the level of a 1% AEP (1:100
ARI) flood event; or
b) are designed and constructed to exclude
water inundation or infiltration and resist
hydrostatic and hydrodynamic forces as a
result of inundation.
1 Solution: ~~ = Acceptable Solution Appendix C
A/S = Altemative Solution nat hazards.doc
N/A = Not applicable to this proposal
178 — 182 Eumundi Noosa Road, Noosaville Page 9See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
0015E24E.001.pdfRelated documentPublic source context ↗
07/0256 - MCU - Bunnings Warehouse [As Published]Related documentApplication case desk ↗
About this file
- File size
- 13.3 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.