NATURAL HAZARDS OVERLAY CODE ; 4 pmm
€
Performance Criteria and Acceptabie Solutions 1 BRISBANE
PERFORMANCE CRITERIA ACCEPTABLE SOLUTIONS SOLUTIONS’ COMMENTS COUNCIL USE ONLY
a Oa DC
018 Community Uses and Infrastructure Uses | $18.1 Community Uses and infrastructure Uses
are able to function effectively during and | are sited and constructed to ensure that floor tevels N/A The subject site is not within a flood hazard area.
immediately after flood events. are not fess than the AEP (or ARI) levels identified
below—
a) Emergency service facilities- 0.2% AEP
(1:500 ARI);
b) Emergency shelter- 0.5% AEP (1:200 ARI);
c) Police station- 0.5% AEP (1:200 ARI);
d) Hospital- 0.2% AEP (1:500 ARI);
e) Electricity substation- 0.2% AEP (1:500 ARI);
f} Water treatment plant- 0.2% AEP (1:500 ARI);
g) Power station- 0.5% AEP (1:200 ARI);
. h) Major electrical switch yard- 0.5% AEP (1:200
ARI); and
i) Store for valuable records or items of historic
or cultural significance- 0.5% AEP { 1:200
~ ARI).
019 All lots have sufficient area that is above the | $19.1 The minimum area above flood level for
1% AEP (1:100 year ARI) flood level or where | each lot, is in accordance with Table 13.11; NA The subject site is not within a flood hazard area.
modelling is not available, the highest recorded
flood level, to safely and adequately accommodate | AND
their intended use.
$19.2 Where the existing roads servicing a
AND development provide a specific flood immunity (as
: determined by Chapter 6 of the Qld Transport Road
020 Development integrates with the natural | and Drainage Design Manual and the Australian
landform rather than modifying the landform to suit | Rainfall and Runoff Guide), all lots have access to
the development.34 the flood free area identified in Table 13.11 that
matches the road immunity; -
AND
$20.1 Flood immunity for development areas is not
achieved by filling land below the 1% AEP (1:100
1 Solution: | % = Acceptable Solution : Appendix C
AIS = Altemative Solution nat hazards.doc
N/A = Not applicable to this proposal .
178 - 182 Eumundi Noosa Road, Noosaville © @ Page 10See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
0015E24E.001.pdfRelated documentPublic source context ↗
07/0256 - MCU - Bunnings Warehouse [As Published]Related documentApplication case desk ↗