WATER SENSITIVE DESIGN CODE 4 mm
Performance Criteria and Acceptable Solutions \ P BRISBANE
fda OL LUO Botan ACCEPTABLE SOLUTIONS SOLUTIONS’ COMMENTS COUNCIL USE ONLY
Water reuse
‘O01 Development uses a combination of detention $1.1 No solution provided v The proposal includes an effective water collection, treatment,
and retention systems to capture run-off from areas storage and reuse system so as to utilise as much run-off as
on the site; possible.
AND
02 Water storage devices must have sufficient $2.1 No solution provided v The proposed water storage device will be adequate for the
capacity having regard to local rainfall pattem and proposed use.
the catchment area of roof or other hard standing
surface;
AND
03 Captured water is utilised for all non-potable $3.1 Captured water is plumbed to be available for v Captured water will be utilised for all extemal uses which accounts
uses on site; all external uses including gardening, irrigation, for approximately 95% of total water usage.
ponds, filling swimming pools and outdoor cleaning,
AND as well as all ground floor toilet cistems and
washing machine cold taps; and
§3.2 Where the captured water is used for toilet
flushing and/or laundry use, an automatic or All toilets will include duet connections to both captured and
manual interchange device that allows altemate ¥ reticulated water.
use of captured water or the reticulated water
supply is installed to ensure that there is a
continual supply of water for sanitary flushing and
laundry use.
04 On-site detention does nat adversely impacton | $4.1 No solution provided v
water requirements downstream of the site where The onsite detention of run-off will not create any detrimental
the water is required to sustain the ecotogy and impacts on the environment downstream.
hydrology of downstream systems (environmental
flows);
AND
1 Solution: =~ = Acceptable Solution Appendix C
A/S = Altemative Solution water sens design.doc
N/A = Not applicable to this proposal
178 -182 Eumundi Noosa Road, Noosaville Page 1See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
0015E24E.001.pdfRelated documentPublic source context ↗
07/0256 - MCU - Bunnings Warehouse [As Published]Related documentApplication case desk ↗
About this file
- File size
- 13.3 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.