WATER SENSITIVE DESIGN CODE ‘4 pmm
¢€
Performance Criteria and Acceptable Solutions 1 BRISBANE
PERFORMANCE CRITERIA ACCEPTABLE SOLUTIONS SOLUTIONS’ COMMENTS COUNCIL USE ONLY
05 Within the Shire Business Centre site, as shown | $5.1 No solution provided N/A
on Map SBC, on-site detention measures are The subject site is not within the Shire Business Centre.
contained within the developed areas of the site,
clear of drainage lines and Open Space Precincts.
Run-off treatment
v Minimal runoff wil! leave the site, however what run-off does leave
06 Run-off that leaves the sife is treated so as not No solution provided the site, will be adequately treated so as to limit the impacts this
to adversely impact on the ecology and hydrology of may have down stream.
downstream environmental flows;
AND
07 Within the Shire Business Centre site, as shown NIA
on Map SBC—
a) run-off treatment occurs within the site ; and
b) drainage lines are only used for final polishing
of run-off.
Town water supply connections
v Backflow will be prevented through the use of suitable plumbing
08 Backflow devices or similar systems ensure $8.1 A suitable backflow prevention device is devices.
water reuse facilities have no impact on the quality installed to protect the potable water within the
of the town mains water. reticulated water supply in accordance with
AS/NZS 3500:2003 Plumbing and Drainage.
Use of natural treatments and systems
v Naturat treatment strategies will form the basis of the water
09 Natural treatment strategies, including grass No solution provided sensitive designs that will be utilised across the site.
swales and bio-retention systems, vegetated
filtration strips and gross pollutant traps, are used
wherever practicable;
AND
010 Within the Shire Business Centre, as shown on N/A The subject site is not within the Shire Business Centre.
Map SBC— where necessary, drainage lines are
ecologically enhanced to ensure that the water
1 Solution: — ¥ = Acceptable Solution Appendix C
AIS = Alternative Solution waiter sens design.doc
N/A = Not applicable to this proposal
178 -182 Eumundi Noosa Road, Noosaville @ @ Page 2See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
0015E24E.001.pdfRelated documentPublic source context ↗
07/0256 - MCU - Bunnings Warehouse [As Published]Related documentApplication case desk ↗
About this file
- File size
- 13.3 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.