SURFACE WATER MANAGEMENT PLAN                                    CJ        ) Cardno
           BUNNINGS WAREHOUSE, NOOSAVILLE

                    The final size and design of the tank will depend upon site conditions, and will be confirmed
                    at the detailed design stage. At this stage, some obvious conclusions may be drawn from
                    the data above; increasing the irrigation rate decreases reliability, but larger tanks served
                    by larger roof areas increase reliability.
                    However, these effects cannot necessarily be extrapolated to reach a guaranteed 100%
                    performance target. The vagaries of rainfall mean that in reality, with a sensibly sized tank
                    serving a realistic roof area, some dry periods will be experienced. The commercial cost of
                    this shortfall must be compared with the capital costs inherent in the tank.
                    To conclude, a 100 kL tank could supply a demand of 3500 litres per day with 95%
            ;       reliability (utilising all of the available roof area). If only 50% reliability is required, then a 10
                    kL tank would suffice (supplied by only half of the roof area). At this point a tank size of
                    100kL is recommended to provide 95% reliability.
                    The model tends towards a conservative assessment in that a daily supply has been
                    modelled.  As described in previous sections, in periods of natural rainfall the artificial
                    irrigation demand of the nursery would decrease (watering being required perhaps every
@                   other day). This effect would lead to a modest improvement on the above figures.
                    5.1       Harvested Rainwater for Toilet Flushing
                    In addition to the above, it is also proposed that the tank be used for toilet flushing (the
                    store will contain seven staff toilets and five public toilets, with associated washing
                    facilities). It is difficult to estimate typical demands in a retail setting, but the Department of
                    Natural Resources and Mines suggest a figure of between 300 and 800 litres per day per
                    100 m? of gross floor area for a ‘Major Shopping Development’ (also, for a ‘shop’, in their
                    Planning Guidelines for Water Supply and Sewerage (March 2005).
                    This equates to a water demand of approximately 40,000 to 54,000 litres per day. As this
                    seems extraordinarily high, the range for ‘Light Industry’ might be more applicable, at            -
                    10,000 to 35,000 litres per hectare, or 7,000 to 24,000 litres per day for the site.
                    As even the 7,000 litre per day figure seems high, the above exercise was repeated for this
                    figure alone, using a full-sized and half sized roof. It is suggested that water use is
                    monitored over several months at several stores to enable the accurate sizing of a
                    rainwater tank.
@                   Table 14    Rainwater Tank Performance
                                                    Demand supplied (%) for each tank size (kL)
                       emand  : roof area
                                        | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 | 150 | 200 |
                      7000 ted: 726m? | 43 | 64 | 2 | e8 | 79 | 77 | 60 | 62 | 64 | a6 | ot | o4
                      7000 ted: s800n® [#0 | 50 | 87 [69 [67 [7] 74] 76 | 78 | ao | 66 | 60 |
                    As may be seen, the tank reliability will obviously drop significantly as the demand is greatly
                    increased. The 100kL tank suggested for irrigation duties in the section above would now
                    only reliably supply 86 per cent of a 7,000 litre per day demand, using a full roof. With half
                    the roof area, the figure drops to 80 per cent reliability.

            Bunnings Warehouse                           Version 3                             8 February 2007
           J:\3501-54\WP\SW MP3.doc                Commercial in Confidence                          Page 15

Used in these records

About this file

File size
13.3 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

0015E24E.001.pdf · 13.3 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.