Original source · versioned page text
05. Hales - Planning Report
Attached to the e-mail Operational Works Application OPW20/0117 - 37 Mossman Crt Noosa Heads.
PROJECT URBAN – 20153 13 Jul 2020
The new boundary wall will be constructed along the boundary line of the property with no portion of the
wall extending past the defined boundary. The boundary wall will be constructed of masonry block and have
a finished level of approximately RL 1.5m AHD. The new jetty will be freestanding and not connect to the
new wall but rather abut up to the same level as the top of the new wall.
Figure 9: Proposed works
The jetty deck will initially slope down slightly keeping a low profile in line with the beach level and then level
out with a finished level of RL 0.8m AHD. The jetty will extend a total of 15m from the boundary wall to the
designated quay line. It will be constructed of timber with 200mm diameter treated hardwood piles for
support. The jetty is to be left-turned with a head of 7000mm in length and 1500m in width. There will be a
handrail down one side of the jetty as required for Australian Standards.
Figure 10: Proposed elevation of the works
A safety ladder will be installed on the inside edge of the jetty head for the safety of the users as
required under the Prescribed Tidal Works Code. In addition, a light that meets with Council
requirements is to be provided on the jetty head to ensure navigational safety during darkness
hours.
Development Assessment Report Page 10 of 42
Operational Works
37 Mossman Court, Noosa Heads 4567