Original source · versioned page text
E - Engineering Code Assessment.pdf
STORMWATER QUALITY AND PROTECTION OF RECEIVING WATERS
Performance Outcomes Acceptable Outcomes Response
PO7 AO7.1 Complies – as above.
Water quality treatment Water quality treatment systems
systems use natural processes are designed to be integrated into
and materials, whenever the landscape consistent with the
possible, and are integrated technical design guideline
into development to enhance published by Healthy Land and
biodiversity and landscape Water by Design for the feature.
benefits. (eg. For Bioretention Basins:
Bioretention Technical Design
Guidelines (October 2014) and for
Wetland Systems the Wetland
Technical Design Guideline (May
2017).
PO8 AO8.1 Not applicable.
Water quality treatment Detailed life cycle costing is
infrastructure to be dedicated provided for the entire treatment Alternative stormwater
as public assets are proven to train system including replacement
quality management
be suitable for its use and of a costs of asset parts.
cost effective and efficient outcomes are inherent in
standard. AO8.2 the design of the driveway
Treatment systems dedicated as and landscaping areas.
public assets are designed to
minimise maintenance, renewal
and adaption costs and the
requirement for specialised
equipment, material or
maintenance techniques.
AO8.3
Vegetated stormwater
management systems to be
dedicated as public assets are
established and maintained during
the maintenance period to ensure
optimal vegetated growth and that
the functional elements of the
system achieve the design
function at the end of the
maintenance period.
PO9 AO9.1 Complies.
Treatment systems are Free draining inlets and outlets are
designed to eliminate or provided to ensure that waters do Stormwater quality
minimise health, safety and not pond for more than 24 hours.
treatment outcomes do not
aesthetic hazards, including
risks associated with insect AO9.2 pose a health threat.
breeding, odour and public Developments are designed to
safety. eliminate retaining walls in excess
of 0.8m for any water quality
treatment device.
Preview the original
The page text is free to read. Previews and downloads of original files need an account.
Log in to previewLog in to download the original (E - Engineering Code Assessment.pdf)