Original source · versioned page text
E - Engineering Code Assessment.pdf
WATER MANAGEMENT
Performance Outcomes Acceptable Outcomes Response
PO6 AO6 Complies.
Waste storage areas are The waste storage area is
designed to contain and constructed of impermeable and
appropriately dispose of durable surfaces and:
leakage from bins and
wastewater from bin a) is bunded and graded so that
washing. washwater and bin leakage are
drained to the sewer or an
on-site effluent disposal system
via a gully within the storage
area;
b) has a bund wall with a
maximum height of 100
millimetres;
c) is serviced by a conveniently
located hosecock and backflow
prevention device, and
connected to a water supply;
and
d) is roofed or otherwise covered if
the storage area is—
i. more than 1m²; or
ii. storing wet waste; or
iii. storing other waste with a
high potential to cause
pollution if washed or
leaked from the bins,
including waste oil or
putrescibles.