Original source · versioned page text
Attachment 4 - Landscape OPW Plans
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn
3 SYZ BE ——\
- 15m spacing \ EB
AUNT 16 UNIT 15
2 BAN rob
5 ALP cae
No tree planting within
services easement
Ay 10 JUN usi
AL 5 LOM hys
hk. - underplanting
Nw]
ti ytl( fet fel pel) tijt +
PROPERTY BOUNDARY
Refer to Engineer's — = fe
Documentation for all be kt | l | ke | l | | | | 5 Bin storage
retaining wall details 3 | S - refer to Architect's documentation for
and specifications § E gate and wall details and specifications
Refer to Engineer's Documentation for all
retaining wall details and specifications
UNIT 2
3 ALP cae
— 1 CUP ana
I \\ = 1001tr
TAX FT
5 LOM SH JN 2 BAN rob
(underplanting) mos 2 BAE vir
3 ALP cae or 4
—
BS ]
3 ALP cae |
L
5 LOM SH
(underplanting) 30 LOM SH
(underplanting)
2 BAN rob
Indicative extent of soil cells to be installed below hardstand
eP| Ensure all road base has been removed (dashed red line)
from planting area - existing-subgrada To provide minimum 4m? soil volume per 100ltr tree planting
to be decompacted no less than 150mm Refer to L201 indicative detail - subject to final detail design.
depth prior to installing topsoil.
Refer to Civil Documentation for edge
thickening detail pertaining to building
UNIT 1 footing/slab.
3 Refer to Detail Plan A for
3 SYZ Pl 3 = landscape treatment f 18 LOM SH
~ 850mm spacing Z ;— 9 JUN usi [ It (underplanting)
3 5 LOM hys r “77-474 1 MEL qui
3 AUS dul “| | | | 7 - q
ro EN EHACE - underplanting 1 I ~ 100ltr
2-MEL qui | { l 3 ALP
~ 100ltr ‘N 3 XAN ful 2 AUS dul 3 LOM SH i cae
—) |
Install Coir mesh —+ : 3 BAN rob \ 5 = 1 BAN rob
to biobasin batters > 1 3 Wall Type 1 with letterboxes & signage plate
- 9m? = 5 MYO ell ly aan | - refer to Engineer's Documentation for wall specifications and details
funderplanting) —N\ elaleatleg \ | Low groundcovers to
4 | l front of signage
x I |
3 ALP cae y
\ 1 CUP ana 1 3 XAN Ful
3 BAN rob
i nasal =—loblte. ‘21 20 LOM SH
SPO JS PROPERTY, BQUNDARY F* PE | 20 LOM NY
Biobasin Planting - 13m? Sete a eeee ee hep per ites 3 MYO ell 4 (edge planting)
Planting at 6/m? fe 1D XAN ful sede fp (underplanting) fedge planting)
11 FIC nod ~ 15% Hea ae atte p tpt ey &
fetes etataf teeters ge Type 1 - refer to detail
11 JUN usi - 15% cf k AP BEEZ I mn
53 LOM hys - 70% eet Pe - r
ys = 10% Edge Type 1 2vtetys* Reinstate all areas of turf damaged
~ refer to detail *.*.*.* y 28 LOM SH during construction works to frontage
Refer to Engineer's
Documentation for all eee ae a
retaining wall details Nata
and specifications st
LEQ ALLEY
\
ROAD
(edge planting)
Refer to Engineer's Documentation for
cross-over details and specifications
NOTE:
Due to service constraints (subsurface services, ENERGEX
requirements for PMT infrastructure) street trees are unable to be
planted within the road reserve.
Buffer planting within services easement
- refer to Landscape Plan L102 for
easement extents and planting details
Bio Basins - Plant Schedule - Total Area = 49m2
BOTANICAL NAME
Ficinia nodosa
Juncus usitatus
Lomandra hystrix
COMMON NAME SIZE NO.
Knobbly Clubrush 75mm tube hh
Common Rush 75mm tube hh
Matt Rush 75mm tube 203
Total tube 291
Landscape Plant Schedule
CODE BOTANICAL NAME COMMON NAME SIZE NO. CODE
Trees FIC nod
BAN int Banksia interifolia Coastal Banksia roottr 1 JUN usi
CUP ana Cupaniopsis anacardiodes Tuckeroo ‘oott 3 |Lom hys
MEL qui Melaleuca quinquernervia Paper Bark soottr 3
Total 7
Shrubs
‘ALP cae Alpinia caerulea Native Ginger 200mm 5
‘AUS dul Ausfromyrtus dulcis Midyim 200mm B
BAE vir Baeckea virgata Twiggy Myrtle 200mm 5
BAN rob Banksia robur Swamp Banksia 200mm B
BAN spi Banksia spinulosa Hairpin Banksia 200mm 10
SYZ BC* Syzygium australe ‘Bush Christmas’ Syzygium Bush Christmas 200mm 9
SYZ Plx_ Syzygium australe ‘Pinnacle’ Syzygium Pinnacle 200mm n
Total 166
Grasses and Groundcovers
JUN usi Juncus usitafus Common Rush 140mm 9
LOM hys Lomandra hystrix Mat Rush 140mm 42
LOM NY Lomandra longifolia ‘Nyalla’ Lomandra Nyalla 140mm 170
LOM SH Lomandra fluviatilis ‘Shara’ Lomandra Shara 140mm 179
MYO ell Myoporum ellipticum Coastal Boobialla 140mm 8
XAN ful Xanthorrhoea fulva Coastal Grass Tree 140mm 2
+ hedging species - spacing indicated on plans
Total 445
NOTE: All 100ltr tree planting to be installed with
a minimum root soil volume of 4m? as per Noosa
Council Decision Notice Condition 10f. dated ‘1st
November 2019.
Wall Type 1 with letterboxes (red —
line) & signage plate (blue line) |
- refer to Engineer's Documentation
for wall specifications and details
8x Paver Type 1 with
gravel mulch surround
- refer to specification
Edge Type 1
- refer
Planting as per
overall plan
a Planting as per overall plan
Edge Type 1 - refer to detail —24
& detail
to detail
DRIVEWAY
Edge Type 1
- refer to detail
DETAIL PLAN A
VERGE \TURF
Fim
LL 3m
SCALE 1:50 (
SCALE 1:100 (A1)
IT_IS THE RESPONSIBILITY OF THE CONTRACTOR
} TO CONTACT THE RELEVANT AUTHORITIES TO
CONFIRM THE LOCATION OF ALL EXISTING SERVICES
PRIOR TO THE COMMENCEMENT OF EXCAVATION
Check all dimensions before commencement of work.
Check Site boundary dimensions from the Title plans
Check Building Boundary clearances by set out.
Notwithstanding the information supplied on this drawing,
the location, depth and extent of underground or
overhead services are to be confirmed ond protected on
site by the contractor prior to commencement of works.
© [5-11-20 | DESIGN AMENDMENTS — FOR APPROVAL | uC
B | 19-08-20] DESIGN AMENDMENTS — FOR APPROVAL _ | uC
7 [19-12-15] FOR APPROVAL ic
Issue Date Description By
SS
Drawing title —
LANDSCAPE PLAN
Project —
PROPOSED INDUSTRIAL
COMPLEX
Client -
DEVCON CAPITAL 9 PTY
LTD
Site -
11 LEO ALLEY ROAD
NOOSAVILLE
Consulting Civil &
&
Structural Engineers
COVEY Project Management
ASSOCIATES PTY LTD
ABN 59 137 305 992 & Planning
124 DUPORTH AVENUE
PO BOX 16 MAROOCHYDORE QLD 4558
E-MAIL: [email protected]
Ph (07) 5443 77 Fax (07) 5443 7577
Approved:
KEVIN COVEY Béng, CPEng, MIEAust, MSPEPNG, RPEQI823
CHRIS CAMP BEng(Hons), MeAust, RPEQ4944
—
Checked : JO Design: JC Drown: JC
as noted Date : DEC 2019
Scales :
Document Stage : OPW
Project : 192297 Sheet No. L100
Digital Ref : 101 Loiscpe Pen issue: = G
This document is copyright and shall not be copied without
writen approval, nor shal it be used except for the
development and the site specified. /
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.