MCU25 0087 - Reference Document - Coastal Hazard Assessment (As Published)
A B C D E F G
3,000 1,600 3,280 6,150 3,620 8,370
conc conc REN conc
8M above
at section NGL
cut
MASTER LIVING
BEDROOM. LIFT
TS PB
LIVING balustrade
T.O.W RL 29.940
REN BLK
18 +29.330
17
16
15
STAIR 1 UPPER LEVEL
14 entry door
FSC
13
12
11
ENTRY
FSC REN
ALFRESCO WC ENS LIFT 10
9
2,700
8
7 c.s.
3,910
PB join
6
5
join
4
3
BATH BEDROOM
join
2 1M above NGL TIM
1
18
17 STEPS
16
15
STAIR
14
13 FSC NGL +25.420
12
11 0 MAIN LEVEL
10 FT
CINEMA 9
8
c.s. door
3,200
7
PB 6
5
3,060
LIFT WORK 4
GYM STORE
2,760
join
3
2
SHOP 1 PB
+22.360
-1 BASEMENT LEVEL
SECTION A
SCALE 1:100 @ A3
DA1 Development Approval application
issue issue / amendment
27.06.25 LF JH ML EN
issue date drawn by
client
Christian Seymour
project
Seymour The Esplanade
location
17 The Esplanade Sunshine Beach
EXT. FINISHES LEGEND BLK masonry blockwork. FT1 floor tile (no refers to type). MR1 metal roof - (no refers to type). SP structural post, refer engineer. SECTION A
AS aluminium screen. C carpet fire fireplace NGL natural ground line. SF structural footing, ref. eng. Aboda Lee Foster • director
Design p - 0424 620 247
Scott Falconer • director
p - 0431 267 157
Group e - [email protected] e - [email protected]
AL aluminium louvres, refer sched. CS concrete slab. flue flue kit PF compliant pool fencing TIM timber cladding. the aboda design group trust
ABN 56 266 884 746
Level 2, 1794 David Low Way Coolum Beach,
Q. 4573. PO box 2449 Noosa Heads Q 4567
t/a aboda design group • BSA License -15058097 • www.aboda.com.au
ASD aluminium sliding door. DP down pipe. GS garage slab. PW parapet wall. TD timber deck. • This drawing is to be read in conjunction with engineers drawings & reports • Construction
to comply with all relevant SAA & NCC Codes & standard Bldg By-law 1975 & as amended •
AFD aluminium framed door. DS driveway slab. HWS hot water service. PS patio slab. TF timber floor. Copyright for design & drawings remain the property of the authors • Verify all dimensions on
site prior to commencement of any works • These drawings are not to be used for scaling.
AFW aluminium framed window. FCA fibre cement awning. HR handrail. PV photovoltaic cells. TFD timber framed door scale Scale as noted @ A3 issue
drawing no.
sun control battens, refer detail. fibre cement ext. cladding. LPG gas bottle. rain water tank. vergola.
WD.601
BA FC LPG RWT VER
BAL1 balustrade-(no refers to type). FG fascia gutter. NGL NRG board SBJ silicone butt jointed glass. DA1