1 2 3 4 5 6 1 2 3 4 5 6
2,400 1,600 3,040 2,960 3,040 2,400 1,600 3,040 2,960 3,040
conc conc CONC
8M above NGL
at section cut
8M above NGL
at section cut
sliding door sliding door
COURTYARD PDR TIM
TERRACE
balustrade
+29.330 +29.330
1 UPPER LEVEL 1 UPPER LEVEL
c.s.
FAMILY PB clothes line
sliding door curtain
louvre PB join
1M above NGL TS REN
3,910
window sh
door
SITTING
NGL ROOM b
1M above NGL
wc
+25.420 +25.420
0 MAIN LEVEL NGL 0 MAIN LEVEL
PB
POOL POOL
3,580
GARAGE GYM
3,060
3,060
CELLAR STAIR
PB
vehicle vehicle
+22.360 +22.360
-1 BASEMENT LEVEL -1 BASEMENT LEVEL
SECTION B SECTION D
SCALE 1:100 @ A3 SCALE 1:100 @ A3
DA1 Development Approval application
issue issue / amendment
27.06.25 LF JH ML EN
issue date drawn by
client
Christian Seymour
project
Seymour The Esplanade
location
17 The Esplanade Sunshine Beach
EXT. FINISHES LEGEND BLK masonry blockwork. FT1 floor tile (no refers to type). MR1 metal roof - (no refers to type). SP structural post, refer engineer. SECTIONS B & D
AS aluminium screen. C carpet fire fireplace NGL natural ground line. SF structural footing, ref. eng. Aboda Lee Foster • director
Design p - 0424 620 247
Scott Falconer • director
p - 0431 267 157
Group e - [email protected] e - [email protected]
AL aluminium louvres, refer sched. CS concrete slab. flue flue kit PF compliant pool fencing TIM timber cladding. the aboda design group trust
ABN 56 266 884 746
Level 2, 1794 David Low Way Coolum Beach,
Q. 4573. PO box 2449 Noosa Heads Q 4567
t/a aboda design group • BSA License -15058097 • www.aboda.com.au
ASD aluminium sliding door. DP down pipe. GS garage slab. PW parapet wall. TD timber deck. • This drawing is to be read in conjunction with engineers drawings & reports • Construction
to comply with all relevant SAA & NCC Codes & standard Bldg By-law 1975 & as amended •
AFD aluminium framed door. DS driveway slab. HWS hot water service. PS patio slab. TF timber floor. Copyright for design & drawings remain the property of the authors • Verify all dimensions on
site prior to commencement of any works • These drawings are not to be used for scaling.
AFW aluminium framed window. FCA fibre cement awning. HR handrail. PV photovoltaic cells. TFD timber framed door scale Scale as noted @ A3 issue
drawing no.
SECTIONS B & D BA
BAL1
sun control battens, refer detail.
balustrade-(no refers to type).
FC
FG
fibre cement ext. cladding.
fascia gutter.
LPG
NGL
LPG gas bottle.
NRG board
RWT
SBJ
rain water tank.
silicone butt jointed glass.
VER vergola.
WD.602 DA1
SCALE 1:100 @ A3
Document Set ID: 24631530
Version: 1, Version Date: 24/03/2026