Subdivision Decision Notice · OPW16/0051

Attached to the e-mail OPW16/0051 - Operational Works Application (REC15/0023).

of 8

Text shows just the words. Original shows the document exactly as it was published.

                                                                                                     REC15/0023


                              Approved Plans
                      2.      Development undertaken in accordance with this approval must generally comply
                              with the approved plans of development. The approved plans are listed in the
                              following table unless otherwise amended by these conditions.
                               Plan No.             Rev.   Plan/Document Name                      Date
                               15-3983AI                   Plan of Proposed Reconfiguration of Lot
                                                    NA                                             23-12-15
                                                           70 on RP217095, prepared by Max
                                                           Watterson + Associates
                      3.      All lot numbering on the subdivision plan to be submitted to Council for compliance
                              assessment must remain as shown on the Approved Plans.
                      4.      The development must be undertaken and operated in a manner that causes no
                              detrimental effect upon the amenity of the neighbourhood by reason of the creation
                              of excessive noise, lighting nuisance or other emissions.
                              ENGINEERING
                              Stormwater Drainage
                      5.      The existing Council’s stormwater drainage pipeline on the property must be
                              reconstructed to be centrally located within the proposed 3.0m wide drainage
                              easement shown on the approved lot reconfiguration plan. The works must be
                              undertaken in accordance with an Operational Works approval in compliance with
                              the relevant sections of Queensland Urban Drainage Manual and supported by a
                              detailed stormwater drainage design prepared and certified by a suitably qualified
                              and experienced Registered Professional Engineer Queensland (RPEQ). The
                              works must generally include:
                              (a)      The replacement and upgrade of the entre length of the pipeline between the
                                       upstream sealed connection pit in Ravenwood Drive and the existing
                                       downstream outlet.
                              (b)      The removal of the redundant existing pipeline.
                              (c)      The reconstruction of the existing kerb inlet pit.
                              (d)      Catering for any existing or required stormwater connection/s into the
                                       pipeline.
                              (e)      Any adjustment to existing public service may be necessitated by the
                                       pipeline replacement.
                              (f)      Any road pavement and frontage reinstatement works associated with
                                       proposed stormwater pipeline works.

                              These stormwater drainage works are “non-trunk infrastructure” for the purposes of
                              the Sustainable Planning Act 2009.
                              Easements
                      6.      A stormwater drainage easement 3.0m wide minimum must be created in favor of
                              Council centrally located over the constructed new stormwater pipeline and
                              structure/s within the site and generally in accordance with the approved lot
                              reconfiguration plan.
                      7.      Unless otherwise agreed in writing by the relevant service provider, any public or
                              third party infrastructure located on the subject site must be placed within an
                              easement registered against the title of the property and in accordance with the
                              requirements of the respective service provider.




                                                                                                            Page 2 of 7


Document Set ID: 20006723
Version: 1, Version Date: 07/01/2016                                                                Print Date: 7 January 2016, 2:28 PM

Used in these records

About this file

File size
582 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Subdivision Decision Notice.pdf · 582 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.