7.3.2 Proposed Water Sensitive Urban Design Devices
The attached MUSIC Model includes proprietary stormwater treatment devices (SPEL
StormFilters and Stormsacks or approved equivalent) and rainwater harvesting and reuse
tanks sized to provide water quality treatment in accordance with Council’s Planning
Scheme Policy. Refer to Table 7.3.2a-b for details of proposed rainwater tanks. Details of
the proposed proprietary water quality treatment devices are included as Appendix G.
Table 7.33-2a: Rainwater Tank Details
Parameter Value
Detached Dwellings
No. Dwellings 2
Reuse Requirement/Dwelling 5kL
Table 7.33-2b: Rainwater Reuse Details
Parameter Value
Detached Dwellings
Lot 2 Demand (75% Balance x 548mm/m²/yr.) 308kL/yr.
Lot 3 Demand (75% Balance x 548mm/m²/yr.) 217kL/yr.
- Source. Water by Design’s – MUSIC Modelling Guidelines.