Skip to the record
Trusted by locals. Built for Noosa.

Original source · versioned page text

Civil Engineering Report

of 76

Page text read automatically using OCR, there may be inaccuracies

Original PDF page 59, section 1. The text section number identifies this passage in the reader.

WATER QUALITY & DRAINAGE CODE
Performance Criteria and Acceptable Solution
23 Bottlebrush Avenue, Noosa Head
22 May 2025
             PERFORMANCE OUTCOMES                                                ACCEPTABLE OUTCOMES                                                             RESPONSE
PO12                                                                AO12.1
                                                                                                                                     No increase in peak runoff from site will occur
Development protects in-stream ecology by                           Where run-off from or within the site passes                     as part of the proposed development. Refer
maintaining pre-development low flow                                through or drains to natural                                     Stormwater Management Plan for further
discharge regimes and maintaining fish                              channels, waterways or wetlands, development                     information.
passages.                                                           protects in-steam ecology by maintaining pre-
                                                                    development low flow discharge regimes in
                                                                    accordance with the frequent flow
                                                                    management objectives in PSP6 Engineering
                                                                    Design Standards - Roads, drainage and
                                                                    earthworks
                                                                    AO12.2
                                                                    Instream structures such as roads, bridges,
                                                                    culverts, and other stormwater infrastructure do
                                                                    not cause barriers to fish passage and facilitate
                                                                    the movement of terrestrial and aquatic fauna
                                                                    along waterway corridors.
                                                                    AO12.3
                                                                    Benthic substrate retains a continuous grade
                                                                    with the direction of flow consistent with the
                                                                    natural bed profile.




https://mpncnetau.sharepoint.com/sites/administration/shared documents/10000-10999/10200-10299/10256/codes/22-05-25 water quality & drainage code_issue a.docx
                                                                                             Page 10

Log in to download the original (Civil Engineering Report.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.