HumeCeptor® system
Maintenance Procedure It may be convenient on larger units to de-water some
of the relatively clean water from the central zone in the
Maintenance of HumeCeptor® is performed using treatment chamber. This will minimise maintenance
vacuum/eductor trucks this ensures that no requirement costs as disposal of essentially clean stormwater can
for entry into the unit is necessary for maintenance. be avoided. Often this can be done in either the sewer
The vacuum truck industry is a well-established sector of or upstream of the pipe (position sandbags to create
the waste management industry cleaning underground temporary storage). However, this should only be done
tanks, sewers and catch basins. with the appropriate authorities consent.
A HumeCeptor® unit is cleaned by adhering to the
following steps: Maintenance Cost
1. Complete a Job Hazard Analysis (JHA) and a Work The costs to clean out a HumeCeptor® will vary based
Method Statement (WMS) before undertaking the on the size of the unit, pollutant volume/type and
maintenance procedure. transportation distances.
2. Prepare the site around the HumeCeptor® for
cleaning. This involves establishing the job site Economies of scale will be achieved where there are
(traffic control if required), assembling cleaning multiple units for a given location. The time to clean the
HumeCeptor® is approximately 30 minutes to an hour,
equipment, positioning the vacuum truck and
excluding transportation and disposal.
ensuring correct equipment is available to use
(including PPE). Disposal costs will vary greatly depending on local
3. Remove the lid above the holding chamber and authority requirements, the type of contaminants
conduct a visual inspection to assess the condition washing off your site and the availability of waste
of the HumeCeptor® and note if there are any disposal facilities.
blockages or lodged debris
4. Check for oil using a dipstick, tube or sampling device It should be noted that these costs would be incurred
during the maintenance of any type or brand stormwater
via the oil sample port.
quality structure and not just the HumeCeptor®.
5. Remove and store any free oil separately using a
small portable pump via the oil sample port:
a. Be sure to skim from the top of the water to
ensure oil contaminants are removed
b. Approximately 300 mm of water should also be
removed from the top of the water column
c. The oil/fuel waste can be disposed of
separately, as this will incur a higher disposal cost
6. Remove the sludge/sediment from the bottom of the
HumeCeptor® using the vacuum truck:
a. The truck’s suction hose should be lowered into
the sump of the device via the outlet riser
b. While extracting the waste, move the hose
around in the opening to ensure that the hose
is sucking from various locations in the sump to
remove all the captured material
c. The extracted waste can usually be disposed of
as general waste at a waste transfer station
7. Clean the interior of the pit using water jet
8. Replace lid, ensuring it is firmly and securely in place
HumeCeptor® system 6