08/0803 - MCU - Multiple Housing Type 2 - Duplex [As Published] · 132008.803
Column 1
Specific Outcomes
for the Detached Housing Zone—50% for a
single storey building and 40% for a double
storey buildin
b) for the Semi-attached Housing Zone—40%
O11 For Multiple Housing Type 2, buildings have
a maximum plot ratio of 0.45:1.
O12
013
014
O15
016 For the Detached house Zone and Semi-
attached Housing Zone—soft landscaping is
provided and retained over a minimum of 20% of the
site area.
Column 2
Probable Solutions (if code assessable)
Column 3
Compliance
Complies - Site cover of 40%
Complies - Plot ratio of 0.45
Not applicable
Not applicable
Not applicable
Not applicable
Complies - 20% of soft landscaping provided.
Roof form
017 Roof forms—
a) contribute positively to the local skyline;
b) complement the character of the locality;
c) use soft and articulated, pitched, skillion or
curved roof forms;
d) avoid low pitched (eg. less than 5 degrees) or
box profiles/parapets; and
e) donot create opportunities for residents to
overlook the private open space areas of
neighbouring properties.
$17.1 The main roof of the building has a roof
pitch no Jess than 5 degrees and has eaves a
minimum of 600mm wide;
AND
$17.2 Buildings and structures do not include roof
top terraces.
Complies - most of the building has eaves
apart from two feature walls. These walls are
only 3.5 metres in length and are located to
the rear of the site. These walls are indicated
by the designer as ‘anchoring’ the building as
the remainder of the structure is well
articulated and steps extensively across and
down the site.
Complies
Flooding and drainage”
018 Buildings and other works are designed and
sited to—
a) provide flood free access to premises and flood
free habitable areas;
b) allow only minor, short term and infrequent
flooding of non-habitable areas;
$18.1 Floor levels for habitable rooms are not
less than the specified minimum floor levels;
AND
$18.2 Where Council infrastructure is available—
a) any drainage (from buildings and land)
flows to that infrastructure; and
Not applicable
Complies - development able to drain to
existing infrastructure. A separate application
for Operational Works will be submitted in this
* Council has mapping of minimum floor levels and flood levels for some parts of the Shire. Contact the Land Development Section of Noosa Shire Council.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
08/0803 - MCU - Multiple Housing Type 2 - Duplex [As Published]Related documentApplication case desk ↗
About this file
- File size
- 3.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.