08/0803 - MCU - Multiple Housing Type 2 - Duplex [As Published] · 132008.803
Column 1
Specific Outcomes
c) ensure drainage does not adversely impact
upon other premises; and
d) ensure filling or excavation does not adversely
impact upon other premises by—
i. causing ponding of water on the site or
nearby land;
ii. increasing flooding, which adversely
affects the safety or use of any land
upstream and downstream; and
adversely affecting the flow of water in
any overland flow path.
Column 2
Probable Solutions (if code assessable)
b) the infrastructure has the capacity to
accept any additional loading.
Column 3
Compliance
regard.
Sloping sites and ridgelines
O19 Development on sloping sites—
a) is responsive to the natural topography of the
site and minimises cut and fill;
b) does not visually dominate the hill slope or
interrupt the skyline;
c) _ is integrated with the natural site
characteristics including vegetation; and
d) for Multiple housing, takes the form of small
separate buildings;
AND
020 On steep slopes or ridgelines which are visible
from the major road network, areas of public open
space, the Noosa River or the beaches—
a) new buildings and structures including
outbuildings, are designed so as not to dominate
or detract from the scenic and environmental
qualities of the site and its setting; and
b) the external colour scheme of buildings is
designed to blend with the natural elements of
its surroundings.
$19.1 Buildings and associated accessways are
not constructed on land with a slope greater than
25% (1 in 4);
AND
$19.2 Buildings are of split level design that step
down the slope or have suspended floor
construction;
AND
$19.3 Cut or
AND
$19.4 The distance between the ground and the
lowest part of the floor of the building does not
exceed 3m;
AND
$19.5 Buildings present no more than 2 or 3
storeys at any one point.
is less than 1.2m in depth;
$20.1 No solution provided
Complies - The building steps down the slope
from the Grant Street frontage and has a
suspended floor construction. Minimal cut and
fill is proposed as a result of this design. The
distance between the ground and the lowest
part of the floor is less than 3 metres.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
08/0803 - MCU - Multiple Housing Type 2 - Duplex [As Published]Related documentApplication case desk ↗
About this file
- File size
- 3.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.