Table Error! No text of specified style in document.-1 — For All Residential Uses

  
 

Column 1
Specific Outcomes

Effects of use
Electricity supply infrastructure

O1 The development does not adversely impact
on existing or future electricity supply
infrastructure;

AND

O2  Alluses and works maintain an adequate
safe distance from electrical infrastructure
including substations, overhead powerlines, power
poles and transformers.

 

     

Column 2
Probable Solutions (if code assessable)

$1.1 No solution provided

$2.1 Development for uses adjacent to or

within 50m of an existing electricity substation

incorporates noise attenuation measures to

mitigate noise impacts;

AND

$2.2 Buildings and structures (including

swimming pools, sheds, tennis courts or

outbuildings) are not constructed under

overhead electricity transmission lines, or within

electricity easements;

AND

$2.3 A minimum separation distance is

maintained from the electricity transmission line

to the closest boundary of habitable buildings

and child activity areas, as follows—

a) 20m for transmission lines up to 132kV,;

b) 30m for transmission lines between 133kV
and 275kV; and

c) 40m for transmission lines greater than
275kKV.

Column 3
ere reir Lites-3

 

Complies

 

 

Environmentally Sustainable Building Design

 

Hot Water Systems

O3 Hot water systems are installed and operated
to support the efficient use of natural resources
and minimise consequent pollution such as
greenhouse gas emissions.

$3.1 All hot water systems installed are—
a) solar systems; or

b) electric heat pump systems; or

c) natural gas or LPG systems; or

d) any combination of a), b) or c).

Conditions may be imposed if required

 

 

Water supply and conservation
04 On-site water storage is designed and

 

$4.1 If in a designated rainwater tank area as

‘ This does not apply to buildings which qualify as Class 1A or 1B structures under the Building code of Australia

 

Water tanks will be provided at rear of site.

    
    
 

 

|

Used in these records

About this file

File size
3.0 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

08_0803 - MCU - Multiple Housing Type 2 - Duplex [As Published].pdf · 3.0 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.