Original source · versioned page text
6.0 Planning Report
Attached to the e-mail Plans and Planning Report - MCU16/0098 & OPW16/0183.
column 1 column 2
Specific Probable solutions (if code assessable)
Outcomes AND
S22.2 Loading and storage areas are well lit or Complies - Loading bay is
can be locked after hours. externally marked and
O23 All premises and provided.
S23.1 All premises are identified by the
access routes are clearly Storage areas are contained
provision of the street number in a prominent
identifiable to all persons, inside the proposed building
location, preferably near the site entry, (i.e. on
particularly emergency and will be locked after hours.
the kerb or letterbox or by signage on the
services personnel. building or site).
Complies- The Proposed
S24.1 The number of entrances and exits are development will have
limited and main building entrances/exits are signage to depict street
O24 All building entries located at the front of the site, in view of the number which
are designed to be street. Where this is not possible, due to site or will be easily identified.
obvious and easily existing building constraints, a well defined path
identifiable. is provided to the entrance/exit; Complies – Entrances to
both the showroom and
AND
administration office are
S24.2 All entrances/exits to buildings, are well lit located to the front of the site.
and signed, and signage includes hours of These can be seen from the
operation; street.
AND Complies - Lighting is
S24.3 Entrances/exits are located to provide a provided over all entrances
direct link to driveways and carparking areas; and signage provides hours of
operation.
AND
S24.4 Recessed doorways are avoided where Complies – The car parking
the recess is of sufficient size to conceal a provides direct access to both
person. Where recessed doorways are the administration office and
unavoidable, measures are used to enhance the showroom.
safety, as follows—
Complies – The doorways
a) good lighting installed; are not recessed.
b) strategically placed mirrors installed;
c) angled approaches provided; or Complies - Windows and main
d) gates which restrict access provided. entrances are located facing
O25 Uses are arranged S25.1 Windows and main entrances are onto the driveway and parking
within buildings and on positioned to allow for casual surveillance. area allowing for casual
sites to enable external surveillance.
areas to be monitored.
S26.1 Communal open spaces, including Complies - An outdoor eating
congregation and seating areas are situated area is located off the north
O26 Communal open where they are in the line of sight of windows,
space, including end of the showroom and
doors and/or balconies of buildings, or can be faces directly onto the
congregation and seating seen from a street or other public space.
areas, is located where it southern driveway access and
can be monitored. onto the street.
S27.1 Buildings or structures that are visible
Complies – The building
from a public street or laneway—
design, external lighting has
a) avoid the use of solid fences and blank been designed to minimise the
O27 Buildings and walls which attract graffiti. Where solid
structures are designed opportunities for vandalism.
blank surfaces are unavoidable,
to minimise opportunities measures in the form of landscaping,
for vandalism. creepers, murals, vandal resistant paint,
etc are used;
Building Suncoast Green (07) 5448 8500
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.