Original PDF page 1, section 1. The text section number identifies this passage in the reader.
PROPOSED MULTIPLE RESIDENCE
51 ELANDA STREET SUNSHINE BEACH QLD
LOT 403 RP48112
CIVIL WORKS
DU
KE
ST
R
SCHEDULE OF DRAWINGS
DWG No. TITLE
001 COVER SHEET & LOCALITY PLAN
002 GENERAL NOTES
003 EXISTING LAYOUT PLAN
010 SITEWORKS OVERALL LAYOUT GROUND
011 SITEWORKS OVERALL LAYOUT BASEMENT
EL
AN
012 DETAILED GROUND LEVEL LAYOUT
DA
014 VEHICLE CROSSOVER LONGITUDINAL SECTION
ST
R
015 FOOTPATH LONGITUDINAL SECTION
T
ROADWORKS DETAILS
RSON S
016
017 DRIVEWAY VERTICAL VEHICLE TRACKING
020 BULK EARTHWORKS LAYOUT PLAN
HENDE
021 BULK EARTHWORKS SECTIONS - SHEET 1
ST
022 BULK EARTHWORKS SECTIONS - SHEET 2
CRANK
041 STORMWATER CATCHMENT LAYOUT
042 STORMWATER LONGITUDINAL SECTIONS - SHEET 1
043 STORMWATER LONGITUDINAL SECTIONS - SHEET 2
PA
CI
044 STORMWATER DETAILS
FI
C
AV
050 WATER & SEWER LAYOUT GROUND LEVEL
PA
E
RK
CRE
S
LOCALITY PLAN
SCALE 1:1000
North Point Approved Project Address Sheet Title
E WHITMORE
N RPEQ 31423
51 ELANDA STREET SUNSHINE BEACH QLD
COVER SHEET AND LOCALITY PLAN
For and on behalf of RECOR Pty Ltd.
Scale ENGINEERING + PROJECT MANAGEMENT Client Details Project Name Sheet Size
SUNSHINE COAST | BRISBANE | SYDNEY
B 26/09/25 ISSUE FOR OPW APPROVAL DP AY 10 0 10 20 30 40 50
www.recorconsulting.com | ABN 89 647 469 707 ARCHEND PROPOSED MULTIPLE RESIDENCE A1
A 21/03/25 ISSUE FOR APPROVAL TVZ AY
SCALE (metres) COPYRIGHT © This drawing is subject to copyright in accordance with the agreement between RECOR Pty Ltd and RECOR's client. This Project Number Sheet Number Revision
1 : 1000 (FULL SIZE) drawing shall only be used for this specific project. This drawing shall not be used for construction until marked as 'Issued For Construction'
Rev Date Revision Description Drawn Check DO NOT SCALE, IF IN DOUBT ASK in the revision description. 20240127 001 B
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of sections 2 to 5 (of 21)
Section 2
GENERAL NOTES 21. NO WORKS ARE TO BE UNDERTAKEN ON LAND OUTSIDE OF THE SITE BOUNDARY f. STORMWATER STRUCTURE BASE SLABS
WITHOUT FORMAL APPROVAL BY THE OWNER/CUSTODIAN OF THAT LAND INCLUDING BUT
1. ALL DIMENSIONS SHOWN ARE IN METERS UNLESS OTHERWISE SHOWN. g. PAVEMENT SUBGRADE
NOT LIMITED TO PRIVATE PROPERTY, ROAD RESERVE, PARKS/OPENSPACE, EASEMENTS.
2. ALL SETOUT ON SITE IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR h. PAVEMENT REINFORCING
22. THE CONTRACTOR SHALL HAVE AN APPROVED SET OF CONSTRUCTION DRAWINGS AND
TO ALLOW FOR ALL MEANS NECESSARY TO ACCURATELY SETOUT THE WORKS. APPROVALS ON SITE AT ALL TIMES. i. PAVEMENT PRIOR TO SEALING (PRESEAL)
3. ALL WORKS TO BE CONSTRUCTED IN ACCORDANCE WITH PROJECT SPECIFICATIONS AND 23. ALL WATER AND SEWER RETICULATION WORKS TO BE CONSTRUCTED IN ACCORDANCE j. RETAINING WALL FOOTING REINFORCING
WHERE FURTHER DETAILS ARE REQUIRED THE CONTRACTOR SHALL REFER TO NOOSA WITH THE SEQ WATER SUPPLY AND SEWERAGE DESIGN AND CONSTRUCTION CODE k. RETAINING WALL BLOCKWORK PRIOR TO CORE FILL
SHIRE COUNCIL DEVELOPMENT GUIDELINES, LOCAL WATER AUTHORITY GUIDELINES, (2013).
ASSOCIATED STANDARD DRAWINGS AND SPECIFICATIONS U.N.O. l. STEEL REINFORCEMENT OF CONCRETE STRUCTURES
3. SHOULD ANY OF THE CONSTRUCTED WORKS BE CONSTRUCTED OUTSIDE OF THE m. PRACTICAL COMPLETION
TOLERANCES SPECIFIED WITHIN THE PROJECT SPECIFICATION AND LOCAL AUTHORITY
STANDARD SIGNS AND LINE MARKING NOTES
n. ON MAINTENANCE
REQUIREMENTS, THE CONTRACTOR WILL RECTIFY AT THEIR COST INCLUSIVE OF ANY 1. GENERAL
ADDITIONAL COSTS INCURRED BY RECOR. o. OFF MAINTENANCE
1.1. ALL SIGNS AND PAVEMENT MARKING IS TO BE IN ACCORDANCE WITH THE
4. EXISTING SERVICES HAVE BEEN PLOTTED FROM SUPPLIED DATA AND AS SUCH THEIR QUEENSLAND TRANSPORT MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES p. ANY OTHER INSPECTION AS SPECIFIED BY LOCAL COUNCIL (REFER DEVELOPMENT
ACCURACY CANNOT BE GUARANTEED. NO RESPONSIBILITY IS TAKEN BY RECOR OR THE (CURRENT EDITION). APPROVAL)
PRINCIPAL FOR THE ACCURACY AND COMPLETENESS OF THIS INFORMATION. IT IS THE 2. SIGNS
RESPONSIBILITY OF THE CONTRACTOR TO ACCURATELY ESTABLISH THE LOCATION AND SERVICES NOTES
LEVEL OF ALL EXISTING SERVICES PRIOR THE COMMENCEMENT OF ANY WORKS. ANY 2.1.
ALL SIGNS TO BE REFLECTORISED CLASS 1 TO AS1906.1:2007 UNLESS NOTED 1. UNLESS OTHERWISE STIPULATED BY TELECOMMUNICATIONS LEGISLATION AT THE TIME
DISCREPANCIES SHALL BE REPORTED TO THE SUPERINTENDENT. CONTRACTOR TO OTHERWISE. OF CONSTRUCTION, THE DEVELOPMENT MUST BE PROVIDED WITH ALL NECESSARY
LOCATE AND PROTECT SERVICES AS REQUIRED DURING PROPOSED WORKS. 2.2. SIGNS ARE TO BE INSTALLED WITH THE FOLLOWING CLEARANCES TO EDGE OF SIGN: CONDUITS, PITS AND PIPES TO ACCOMMODATE THE FUTURE CONNECTION OF OPTIC
LOCATION CLEARANCE NO KERB 600 BEHIND GUIDE POSTS BARRIER KERB 300 FROM FIBRE TECHNOLOGY TELECOMMUNICATIONS.
5. THE CONTRACTOR IS TO CHECK THROUGH LOCATING, POTHOLING AND SURVEY ALL FACE MOUNTABLE KERB 500 FROM FACE OF KERB.
CRITICAL CONNECTION POINTS FOR ALL CIVIL WORKS SHOWN ON THE DRAWINGS 2. CERTIFICATION MUST BE SUBMITTED TO COUNCIL FROM ALL RELEVANT SERVICE
2.3. PARKING CONTROL SIGNS TO BE MOUNTED TO FACE APPROACHING TRAFFIC AT 45° PROVIDERS (ENERGEX, NBN AND UNITYWATER) WHICH CERTIFIES THAT THE
INCLUDING ANY POTENTIAL EXISTING SERVICES CLASHES PRIOR TO COMMENCEMENT OF TO KERB OR CARRIAGEWAY EDGE. ALL OTHER SIGNS TO BE TURNED AWAY BY 5°
CIVIL WORKS. CONTRACTOR TO IMMEDIATELY REPORT ANY DISCREPANCIES TO RECOR DEVELOPMENT HAS MET THE REQUIREMENTS OF THIS DECISION NOTICE AND ALL
FROM THE NORMAL TO APPROACHING HEADLIGHT.
AND AWAIT FORMAL DIRECTION PRIOR TO COMMENCING CIVIL WORKS. APPLICABLE LEGISLATION AT THE TIME OF CONSTRUCTION.
3. SIGN SUPPORTS
6. ON COMPLETION OF SERVICES INSTALLATION, ALL DISTURBED AREAS SHALL BE
3.1. SLEEVED SIGNS SUPPORTS ARE TO BE PROVIDED IN ALL AREAS WHERE THEY ARE
GEOTECHNICAL NOTES
RESTORED TO ORIGINAL LEVEL, INCLUDING KERBS, FOOTPATHS, CONCRETE AREAS, 3. ALL WORKS MUST BE CARRIED OUT IN ACCORDANCE WITH THE RECOMMENDATIONS
IN A PAVED SURFACE.
GRAVEL AREAS, GRASSED AREAS AND ROAD PAVEMENTS. CONTAINED IN THE PROPOSED UNIT DEVELOPMENT REPORT PREPARED BY TECTONIC ON
4. LINEMARKING
7. CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR OF ANY DAMAGE TO THE 30th OF SEPTEMBER 2024, REF. 24265-001-REV0.
AUTHORITY/COUNCIL'S INFRASTRUCTURE. SUCH REPAIR OR REINSTATEMENT TO BE 4.1. REDUNDANT LINEMARKING IS TO BE GROUND OFF.
CARRIED OUT IMMEDIATELY TO THE SATISFACTION OF INFRASTRUCTURE 4.2. THERMOPLASTIC LINEMARKING TO BE USED FOR ALL CONCRETE. EARTHWORKS AND RETAINING WALLS NOTES
OWNER/MANAGER / AUTHORITY/COUNCIL. 1. ALL EARTHWORKS AND ASSOCIATED BATTERS/RETAINING STRUCTURES, BOTH ABOVE
JOINTING NOTES AND BELOW GROUND LEVEL, BOTH TEMPORARY AND PERMANENT, MUST BE CONTAINED
8. CONTRACTOR TO UNDERTAKE ALL WORKS IN ACCORDANCE WITH ALL WORKPLACE ENTIRELY WITHIN THE SUBJECT SITE UNLESS WRITTEN PERMISSION FROM THE
HEALTH AND SAFETY REQUIREMENTS. RESPECTIVE LANDOWNER(S) IS PROVIDED TO COUNCIL. ALL EARTHWORKS MUST BE
1. ALL JOINTING AND CONCRETE TO BE IN ACCORDANCE WITH THE REQUIREMENTS OF UNDERTAKEN IN ACCORDANCE WITH THE PROVISIONS OF AUSTRALIAN STANDARD
9. WHERE ANY EXCAVATION OR CONSTRUCTION WORKS ARE TO BE IN CLOSE PROXIMITY
AS3727.1:2016. AS3798: GUIDELINES ON EARTHWORKS FOR COMMERCIAL AND RESIDENTIAL
TO NEIGHBOURING LOT BOUNDARIES OR INFRASTRUCTURE, CONTRACTOR TO ALLOW IN
SCOPE OF WORKS TO PROVIDE ALL MEASURES NECESSARY TO ENSURE THE INTEGRITY 2. SAW CUT JOINTS MUST BE: DEVELOPMENTS.
OF EXISTING BOUNDARIES AND INFRASTRUCTURE. THIS MAY INCLUDE THE USE OF LOW 2.1. BETWEEN 41 AND 31 OF CONCRETE PAVEMENT DEPTHS. 2. WHERE THE DEVELOPMENT INVOLVES EXCAVATION OR FILLING OVER, OR ADJACENT TO,
VIBRATION EQUIPMENT, TRENCH SHORING ETC AS REQUIRED. 2.2. CLEARED OF ANY DEBRIS FROM THE CUTTING METHOD. DRAINAGE, WATER SUPPLY OR SEWERAGE INFRASTRUCTURE, ALL ACCESS CHAMBER
10. PRIOR TO THE CONTRACTOR COMMENCING ANY WORKS DETAILED ON THESE DRAWINGS, 2.3. PERFORMED WITHIN 6 TO 12 HOURS OF FINISHING CONCRETE POURS. SURFACE LEVELS MUST BE ADJUSTED TO PROVIDE A FREEBOARD OF 100MM ABOVE THE
THE CONTRACTOR IS TO NOTIFY RECOR AND RECEIVE WRITTEN CONFIRMATION THAT 3. DOWELL BARS MUST BE INSTALLED EXACTLY 90° TO THE FACE OF JOINT TO ALLOW FINISHED GROUND SURFACE LEVEL.
WORKS CAN COMMENCE. EXPANSION AND CONTRACTION MOVEMENTS. 3. ALL RETAINING WALLS MUST BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH
11. CONTRACTOR TO PROVIDE AS CONSTRUCTED DRAWINGS FOR ALL CONSTRUCTED 4. JOINTING LAYOUT TO BE CONFIRMED BY SUPERINTENDANT PRIOR TO CONSTRUCTION THE PLANNING SCHEME AND MUST BE CERTIFIED BY AN RPEQ WHERE EXCEEDING 1.0M IN
WORKS IN ACCORDANCE WITH LOCAL GOVERNMENT REQUIREMENTS. UNLESS COMMENCING. LAYOUT SHOULD AVOID ACUTE ANGLES IN THE CONCRETE SLAB AND HEIGHT. ALL RETAINING WALLS THAT ARE PUBLICLY ACCESSIBLE AND EXCEED 1.0M IN
OTHERWISE ADVISED BY RECOR CONTRACTOR TO NOTE COUNCILS ADAC AVOID MISMATCHED JOINTS. HEIGHT MUST BE FITTED WITH A COMMERCIAL GRADE SAFETY FENCE.
REQUIREMENTS.
5. JOINT SEALANTS WHERE USED MUST ADHERE TO SIDE OF JOINT FACES ONLY AND SHALL
12. CONTRACTOR TO UNDERTAKE ALL WORKS IN ACCORDANCE WITH RELEVANT NOT EXTEND ABOVE SIDES OF JOINTS ONTO THE SLAB SURFACE.
APPROVALS.
6. DOWEL BARS ARE TO BE
13. CONTRACTOR TO ALLOW TO LIASE/CO-ORDINATE WITH ELECTRICAL, LANDSCAPE AND
OTHER SERVICE CONTRACTORS THROUGHOUT CIVIL CONSTRUCTION. 6.1. FOR 100MM THICK SLAB, 12MM Ø OF LENGTH 300MM AND SPACED AT 400MM
CENTRES
14. CONTRACTOR TO ORGANISE ALL DEMOLITION PERMITS PRIOR DEMOLITION WORKS 6.2. FOR 125MM THICK SLAB, 16MM Ø OF LENGTH 350MM AND SPACED AT 300MM
COMMENCING ON SITE. CENTRES
15. CONTRACTOR TO ALLOW TO DEMOLISH ALL EXISTING STRUCTURES, ROADS AND 6.3. FOR 150MM THICK SLAB, 20MM Ø OF LENGTH 400MM AND SPACED AT 300MM
SERVICES WITHIN LIMIT OF WORKS AND REMOVE FROM SITE U.N.O. CENTRES
16. CONTRACTOR TO UNDERTAKE DILAPIDATION REPORT FOR ADJOINING PROPERTIES AND
COUNCIL ROADS AND VERGES PRIOR TO COMMENCEMENT OF ANY WORKS ON SITE. INSPECTIONS:
17. CONTRACTOR TO CLEAR AND GRUB ALL VEGETATION ON SITE AS IDENTIFIED IN THE THE FOLLOWING INSPECTIONS MUST BE COMPLETED BY RECOR ENGINEERS BEFORE
APPROVED VEGETATION MANAGEMENT PLAN. CONTRACTOR TO ENSURE ALL TREE ENGINEERING CERTIFICATION WILL BE ISSUED. THE CONTRACTOR IS TO PROVIDE A MINIMUM
ROOTS AND STUMPS ARE COMPLETELY REMOVED AND BACKFILLED TO LEVEL 1 OF 72 HOURS NOTICE TO RECOR FOR REQUIRED INSPECTIONS. SHOULD THE
SUPERVISION. CONTRACTOR TO ALLOW TO MULCH ALL CLEARED VEGETATION AND CONTRACTOR FAIL TO REQUEST AN INSPECTION, THE CONTRACTOR WILL BE RESPONSIBLE
STOCKPILE ON SITE OR REMOVE FROM SITE AS DIRECTED. FOR ALL COSTS TO ALLOW FOR THE WORKS TO BE INSPECTED TO THE SATISFACTION OF
18. DRAWINGS TO BE READ IN CONJUNCTION WITH ARCHITECT, SURVEYOR, HYDRAULICS, RECOR. ANY INSPECTIONS THAT FAIL ARE TO BE RE-INSPECTED WITH ALL REINSPECTION
ETC. CONSULTANT AND CONTRACTOR DRAWINGS. COSTS TO BE PAID BY THE CONTRACTOR.
19. CONTRACTOR TO PREPARE AND HAVE APPROVED BY RELEVANT AUTHORITY: ROAD a. PRESTART
OPENING PERMIT AND TRAFFIC MANAGEMENT PLAN FOR ALL WORKS WITHIN COUNCIL b. EARTHWORKS - FINAL STRIPPING OF TOPSOIL, INSTALLATION OF SEDIMENT AND EROSION
ROAD RESERVES. CONTRACTOR TO ALLOW FOR ALL COSTS ASSOCIATED WITH CONTROL MEASURES UNSUITABLE GROUND
IMPLEMENTATION OF THE TMP.
c. SIDE AND CUT OFF DRAINS
20. ALL WORKS TO BE COMPLETED IN ACCORDANCE WITH ALL LOCAL AUTHORITY
APPROVALS RECEIVED FOR THE PROJECT AND IN ACCORDANCE WITH OPW APPROVALS d. STORMWATER PIPE LAID ON BEDDING PRIOR TO BACKFILL
BY COUNCIL. e. STORMWATER TRENCH BACKFILLED PRIOR TO PAVEMENT PLACEMENT
North Point Approved Project Address Sheet Title
E WHITMORE
RPEQ 31423
51 ELANDA STREET SUNSHINE BEACH QLD
GENERAL NOTES
For and on behalf of RECOR Pty Ltd.
Scale ENGINEERING + PROJECT MANAGEMENT Client Details Project Name Sheet Size
SUNSHINE COAST | BRISBANE | SYDNEY
B 26/09/25 ISSUE FOR OPW APPROVAL DP AY www.recorconsulting.com | ABN 89 647 469 707 ARCHEND PROPOSED MULTIPLE RESIDENCE A1
A 21/03/25 ISSUE FOR APPROVAL TVZ AY COPYRIGHT © This drawing is subject to copyright in accordance with the agreement between RECOR Pty Ltd and RECOR's client. This Project Number Sheet Number Revision
drawing shall only be used for this specific project. This drawing shall not be used for construction until marked as 'Issued For Construction'
Rev Date Revision Description Drawn Check DO NOT SCALE, IF IN DOUBT ASK in the revision description. 20240127 002 B
Section 3
S
42.
CP
S
52
BUP106270
CP
S
42.
83
BUP102822
4
.9
43
S
S
42.
95
NOTES:
45
. 77
6
.7
S
45 1. FOR GENERAL NOTES REFER DWG 002, WHICH IS TO BE REQUESTED AND
VIEWED PRIOR TO COMMENCEMENT OF CONSTRUCTION IF NOT SUPPLIED.
2. THE CONTRACTOR WILL MAKE HIMSELF FULLY AWARE OF THE EXISTING
S
FEATURES OF THIS SITE AND ENSURE ANY ADDITIONAL WORKS NOT
45
.6
.98
2
.38 42 SHOWN ON THIS PLAN ARE INCLUDED IN THE CONTRACT.
46
CP
46
3. LOCATION AND DEPTH OF EXISTING SERVICES BASED ON SURVEY, DBYD
.2
GTP689
6
.10
S
46 AND COUNCIL RECORDS. IT IS THE CONTRACTORS RESPONSIBILITY TO
CONFIRM ACTUAL LOCATION AND DEPTH PRIOR TO CARRYING OUT ANY
EXCAVATION OR TRENCHING WORKS.
S
45
4. CONTRACTOR TO LOCATE AND PROTECT ALL EXISTING SERVICES ON SITE
.3
7
46
.9
7
.1
46 PRIOR TO COMMENCEMENT OF WORKS.
6R
46
.03
B
.72
.7
46 43
4
RT
5. CONTRACTOR TO ORGANISE ALL DEMOLITION PERMITS PRIOR TO ANY
S
0 DEMOLITION WORKS COMMENCING ON SITE.
47.0
T 6. ALL VEGETATION WITHIN THE LIMIT OF WORKS TO BE CLEARED, MULCHED
2R
8 .2
4
5R
B AND REMOVED FROM SITE IN ACCORDANCE WITH APPROVED VEGETATION
47
46
S
.4
.1
.7
47 CLEARING PLAN (BY OTHERS) OR IF SCHEDULED STOCKPILE FOR USE BY
9
0
45
.6
LANDSCAPER.
47
3R
.2
B
9
2
.3 7. CONTRACTOR TO LOCATE ALL EXISTING UTILITIES ON SITE AND MAKE
46
RF 47 3
45
S
.8
.7
36 46 SUITABLE ARRANGEMENTS TO HAVE DISCONNECTED PRIOR TO
1
.23
2.
RT
52
5
46.67
.6
DEMOLITION WORKS BEGINNING.
2R
F
.3
8 .32 8. PRIOR TO THE CONTRACTOR COMMENCING ANY WORKS DETAILED ON
47 43
47
S
RB
46
47
.3
9 THIS DRAWING, THE CONTRACTOR IS TO NOTIFY RECOR AND RECEIVE
4
.6
.2
.3
.75
4
47
0
46 WRITTEN CONFIRMATION THAT WORKS CAN COMMENCE.
3 RT .3
9
.20
.6 47 F .32 43 S
48 7R 44 S S S 9. CONTRACTOR TO UNDERTAKE DILAPIDATION REPORT FOR ADJOINING
.1
47
53
.3
PROPERTIES AND COUNCIL ROADS AND VERGES PRIOR TO
4
52
.96
44
.6
43 COMMENCEMENT OF ANY WORKS ON SITE.
47
2
.98
RF
. 37
.63
45
.06 43
47
.5
44 10. CONTRACTOR TO ALLOW TO DEMOLISH ALL EXISTING STRUCTURES,
1R
47.
46
.3
18
46
4
B
.6
46 .91
.6
Section 4
0
B ROADS AND SERVICES WITHIN LIMIT OF WORKS AND REMOVE FROM SITE
.8
8
9R
46
.4 4R
1
47 .2
T
45 .83 U.N.O.
53
RT 44
LOCATION AND EXTEND OF EXISTING
.4
.71
6R
46 RB
F
ELECTRICAL CONNECTION TO BE CONFIRM RB
52
47
9 .53 11. WHERE NECESSARY, CONTRACTOR SHALL OBTAIN ALL NECESSARY
.3
45
.3
.5
6R
5
ON-SITE. REMOVAL AND REPLACEMENT TO 47
F
.17 APPROVALS TO CARRY OUT SERVICES RELOCATION OR ALTERATIONS.
BE ARRANGED BY SITE SUPERINTENDANT 47 RT CP
46 .84
53
RT .86
46
46
.7
.1
47
47
B
4
9.
7R
B 6 R
.10
BUP3585
.6
4 7R .3
F
47 46
1
.5 T
47 00R EXISTING BUILDING
47
.
.6
4 9 TO BE DEMOLISHED RT .78
0
3 .87 45
7.3 46 B
4
.90 .64R
46 46
OE RT
0
RT 49.8
. 83
49 4
.8
49
49
.51
49
.3 2 T
49 .86R
.9
47
.8
59
2
0
49 7.
4 .17 .98 LEGEND:
52
1 47 46
OE
.3
.6
7R
47
F
4
.6
47 EXISTING CONTOURS
49
.82 55 .60
53
87 49 .
.9
. RT 47 47
.4
EXISTING 49
6
6
87 .55
RF
49. 2 47
TELSTRA PIT .9 .33 EXISTING BUILDING
49 47
B
3R
OE
49
4 RT .6
.6 47 EXISTING KERB AND CHANNEL
.17
.9
47
0
48
85
9.
49
4
.93 .60 EXISTING FENCE
49
.9
49 47
RB
6
.94
.73
47
49
W EXISTING TELSTRA
0 T
.6
49.97 .8
49
49.92 49
5
4
.6
.9
49 RB
7
49
49.71
.79
.7
49
.92 47 OE EXISTING OVERHEAD ELECTRICAL
OE 9
.7
49
7T
W
K
49.6
8 W EXISTING WATER
49
.6
6
49.68 RB
.01 S EXISTING SEWER
48
49
W F
.88
49
90 7R
.61
. 47
.9
49 .3
1C
52
EB
.90
EXISTING TREE
R
7
.7 49
49 RT .13
W .81 48 EXISTING TELSTRA PIT
49
CP
OE
49
.54 RT
E B 49
.50 . 81
SP193676 WM EXISTING WATER METER
49
RT
W RB .81
.49 49 ADJACENT BOUNDARY
49
49
RB
.15
.48
8
49
.4 49
EB
PROPOSED BOUNDARY
49
W .95
.5
48
5C
R
0
.4
49
49
.33
W .25
OE
49
EB
49.24
.07
49
W
.17
49
49
.08
EB
OE
49
.18
CR
.3 3
49
FD
North Point Approved Project Address Sheet Title
E WHITMORE
N RPEQ 31423
51 ELANDA STREET SUNSHINE BEACH QLD
EXISTING LAYOUT PLAN
For and on behalf of RECOR Pty Ltd.
Scale ENGINEERING + PROJECT MANAGEMENT Client Details Project Name Sheet Size
SUNSHINE COAST | BRISBANE | SYDNEY
B 26/09/25 ISSUE FOR OPW APPROVAL DP AY
1 0 1 2 3 4 5
www.recorconsulting.com | ABN 89 647 469 707 ARCHEND PROPOSED MULTIPLE RESIDENCE A1
A 21/03/25 ISSUE FOR APPROVAL TVZ AY SCALE (metres) COPYRIGHT © This drawing is subject to copyright in accordance with the agreement between RECOR Pty Ltd and RECOR's client. This Project Number Sheet Number Revision
1 : 100 (FULL SIZE) drawing shall only be used for this specific project. This drawing shall not be used for construction until marked as 'Issued For Construction'
Rev Date Revision Description Drawn Check DO NOT SCALE, IF IN DOUBT ASK in the revision description. 20240127 003 B
Section 5
S
S
>
REFER TO BASEMENT PLAN
S
FOR STORMWATER SYSTEM
>
>
UNDER BASEMENT LEVEL
S
3-3
>
>
2.0m x 2.5m x 1.0m DEEP CONCRETE
S
DETENTION TANK. MIN. 5.0m3
S
REQUIRED STORAGE VOLUME.
>
>
S
>
>
S
>
1-2
>
6-1
S
S
>
>
S
>
>
REFER TO BASEMENT LAYOUT
S
DRG C011
4-3 1-5
>
S
S
>
REFER TO SHEET 017 FOR VEHICLE
TRACKING LONGITUDINAL SECTION.
S
>
S
>
S
S
3-3
>
A4
04
S S
8
45.
1-2
0
46.
8-1
S
>
2
46.
6-1
.96
4
46.
43
>
T
6
EN
46.
7-1
S
3 M
8
3.6
E
46.
AS
4-3
4
0
B
47.
CONNECT TO EXISTING TO
2
47.
STORMWATER INLET PIT AY
S
4
REFER TO ARCHITECTURAL
47.
W
VE PLANS FOR BUILDING DESIGN
6
I
47.
DR
8
47.
S S S
0
8-1
48.
ENLARGEMENT
43.2
6
2
.9
48.
43
7-1
43 .4
43 .6
4
43
.63
48.
SCALE 1:50 ACO K300 KLASSIKDRAIN
44 .8
43
44.2.0
OR SIMILAR APPROVED 6
48.
TO CONNECT TO 2-1
4 4.4
4 4.6
8
45.40.8
48.
4
0
49.
4 5.2
LID TO BE LIFTED 100mm REFER TO
45.56.4
ACO K300 KLASSIKDRAIN 5-1
4
ABOVE DESIGN SURFACE
LEGEND
OR SIMILAR APPROVED ENLARGEMENT
TO CONNECT TO 1-4
49.2
2-1
45.8
EXISTING POWER POLE TO BE RELOCATED
46.0
OR MAIN TO BE RELOCATED UNDERGROUND.
1-1
46.2
SUBJECT TO ENERGEX APPROVAL.
46.4
REINSTATE VERGE AND
49.4
46.6
KERB TO MATCH EXISTING EXISTING CONTOURS
46.8
EXISTING BUILDING
PROPOSED VEHICLE CROSSOVER EXISTING KERB AND CHANNEL
47.0
IN ACCORDANCE WITH IPWEA STD .6
5.4
49 EXISTING FENCE
DRG RS-049 & RS-050
0m
47.2
VISITORS PARKING 4-1 EXISTING TELSTRA
T
47.4
W
OE EXISTING OVERHEAD ELECTRICAL
47.6
W W EXISTING WATER
47.8
4.
49.
00
S
48.0
6 EXISTING SEWER
m
W
EXTERNAL FOOTPATH RAMP AND STAIRS NOTES: EXISTING TELSTRA PIT
49.6
48.2
ACO K100 KLASSIKDRAIN WITH WM EXISTING WATER METER
W
1. THE EXTERNAL FOOTPATH, RAMP AND STAIRS SHALL BE
5.
HEELSAFE GRATE OR SIMILAR
PROPOSED CONTOURS
48.4
00
APPROVED TO CONNECT TO 46.0
m
STRUCTURE 4-1
CONSTRUCTED IN ACCORDANCE WITH AUSTRALIAN STANDARDS AS
ADJACENT BOUNDARY
48.6
W
0m 1428.1-2001, AS1428.2-1992, AND THE PROPOSED DESIGN.
1.5
2.5
2. WARNING TACTILE INDICATORS (TGSIs) ARE TO BE PLACED AT THE PROPOSED BOUNDARY
m
48.8
PROPOSED 2.5m WIDE
W
CONCRETE FOOTPATH
TOP OF ALL RAMPS AND STAIRS AND AT THE TOP AND BOTTOM OF PROPOSED STORMWATER PIPE
ALL RAMPS AND STAIRS WHERE THE LANDING WIDTH EXCEEDS 3.0m
49.0
EL
AN
WIDE. TACTILE INDICATORS ARE TO BE PLACED IN ACCORDANCE PROPOSED STORMWATER PIT
DA
49.2
W
ST
WITH AS1428.4 - 2009. RETAINING WALL (BY OTHERS)
RE
ET
3. CAMBER AND CROSSFALL MUST NOT EXCEED 1:40 IN ACCORDANCE
> > > PROPOSED SWALE
W WITH AS1428.1-2001
. 50m 49.2 4. STAIRS AND RAMPS ARE TO BE SLIP RESISTANT SURFACES IN PROPOSED CONCRETE PAVEMENT
0 ACCORDANCE WITH AS 4586-2013 AND HB 197:1999
PROPOSED FOOTPATH
PROPOSED 1.5m WIDE
CONCRETE FOOTPATH PROPOSED BITUMEN PAVEMENT
PAVEMENT CUTBACK EXTENT
PROPOSED TYPE 2 HANDRAIL IN ACCORDANCE WITH
MATCH NEATLY TO IPWEA STD DRG. GS-044 OR OTHER SIMILAR
EXISTING FOOTPATH PRODUCT NOMINATED BY ARCHITECT AND
APPROVED BY COUNCIL AND TO COMPLY WITH
CLAUSE 10 OF AS 1428.2-1992 ACCESS AND MOBILITY
.53
49
North Point Approved Project Address Sheet Title
E WHITMORE
N RPEQ 31423
51 ELANDA STREET SUNSHINE BEACH QLD
SITEWORKS OVERALL LAYOUT GROUND
For and on behalf of RECOR Pty Ltd.
Scale 1.0 0 1.0 2.0 ENGINEERING + PROJECT MANAGEMENT Client Details Project Name Sheet Size
SCALE (metres) SUNSHINE COAST | BRISBANE | SYDNEY
B 26/09/25 ISSUE FOR OPW APPROVAL DP AY
1 0
1 : 50 (FULL SIZE)
1 2 3 4 5
www.recorconsulting.com | ABN 89 647 469 707 ARCHEND PROPOSED MULTIPLE RESIDENCE A1
A 21/03/25 ISSUE FOR APPROVAL TVZ AY SCALE (metres) COPYRIGHT © This drawing is subject to copyright in accordance with the agreement between RECOR Pty Ltd and RECOR's client. This Project Number Sheet Number Revision
1 : 100 (FULL SIZE) drawing shall only be used for this specific project. This drawing shall not be used for construction until marked as 'Issued For Construction'
Rev Date Revision Description Drawn Check DO NOT SCALE, IF IN DOUBT ASK in the revision description. 20240127 010 B
The text continues on section 6.