                                                                                      SWMS: 08 – Portable Power Tools
Safe Work Methods
                                                                                  H                    Controls / Work Methods                          Responsible
                                                                                                                                                                             Residual Risk
          Job Steps                   Potential Hazards        L      C     R     O            1. Eliminate 2. Substitute 3. Isolate 4. Engineer        Person/s for
                                                                                  C                             5. Admin 6. PPE                       Monitor & Review       L     C         R
                                                               B      E     E     5      Portable power tools are to be visually inspected by        Competent              D     4     H
Pre-use inspection of portable    Use of damaged / faulty
                                                                           24             the operator prior to use.                                  Operator                           14
power tools                       equipment
                                                                                         Portable power tools are to comply with the relevant
                                                                                 5        Australian Standard(s).                                     Licenced
                                                                                                                                                      Electrician
                                                                                         A licenced electrician is to inspect tools and leads at a
                                                                                 5        maximum interval of 3 months (Nationally) and 6
                                                                                          months (VIC).
                                                                                 5-3     Do not use a tool that has been identified as damaged
                                                                                          or faulty. Damaged / faulty equipment is to be
                                                                                          immediately removed from service, affixed with a
                                                                                          “Danger Do Not Operate” tag and are not to be used
                                                                                          until repaired by the supplier/manufacturer or
                                                                                          replaced.
                                                                                         Do not use tools that are damp or wet or have been
                                                                                 5        exposed to the rain unless they have been examined
                                                                                          by a licenced electrician and cleared for safe use.
                                                               B      4     E     4        Ensure all guarding is in place and inspect the tool      Competent              D     4     H
Portable Power Tool Use           Contact     with    or
                                                                           21               prior to use.                                             Operator                           14
(General)                         entanglement in moving
                                                                                  5        Ensure firm footing on work platform / ground.
                                  parts
                                                                                  5        The equipment is to be allowed to stop moving before
                                                                                            being placed on the ground or work surface.
                                                                                           Electrically isolate (or disconnect) all portable power
                                                                                  3         tools prior to changing blades, bits, or undertaking
                                                                                            other general maintenance procedures.
                                                                                  5        Maintain a safe distance from moving parts when
                                                                                            operating power tools.
                                                                                           Do not wear jewellery and ensure loose clothing and
                                                                                  1
                                                                                            long hair is secured to protect against entanglement.


584 Milton Road TOOWONG QLD 4066                            SWMS Approved by:    Jamie Gilbert                                                                  VERSION 6 – September 2015
P: (07) 3335 5000 F: (07) 3335 5005                         Position: National Health & Safety Co-ordinator                                                                        Page 61
ABN: 52 009 778 330

Used in these records

About this file

File size
16.2 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

WHSMP.pdf · 16.2 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.