                                                                                            SWMS: 08 – Portable Power Tools
Safe Work Methods
                                                                                        H                      Controls / Work Methods                         Responsible
                                                                                                                                                                                 Residual Risk
          Job Steps                   Potential Hazards              L      C     R     O              1. Eliminate 2. Substitute 3. Isolate 4. Engineer       Person/s for
                                                                                        C                               5. Admin 6. PPE                      Monitor & Review    L     C         R
                                                                     B      4     E     6        Safety glasses and/or face shield to be worn.              Competent           D     4     H
                                  Contact with or impact
                                                                                 21                                                                          Operator                        14
                                  from flying particles
                                                                     C      5     E     5               All tools are to be used in accordance with the     Competent           D     4     H
                                  Contact with live exposed
                                                                                 22                      manufacturer’s specifications.                      Operator                        14
                                  electrical parts / electrical
                                  hazards                                                               Only competent personnel are permitted to
                                                                                        5                operate portable electrical tools on-site.

                                                                                        5               All power is to be sourced from RCD protected
                                                                                                         wiring.
                                                                                        3               Electrically isolate (or disconnect) all portable
                                                                                                         power tools prior to changing blades, bits, or
                                                                                                         undertaking other general maintenance
                                                                                                         procedures.
                                                                                        1               Double adaptors are not to be used on site.
                                                                                                         Multi plug outlet devices are to be of a type
                                                                                                         complying with AS 3105 and incorporate over
                                                                                                         current protection RCD’s.
                                                                                        1
                                                                                                        Leads are not to be positioned in mud, water or
                                                                                                         areas where they may be damaged or create a
                                                                                                         tripping hazard. Measures are to be taken to
                                                                                                         protect or suspend electrical leads and ensure
                                                                                                         that they are not allowed to wrap around
                                                                                                         scaffolds or falsework – use hanging brackets
                                                                                                         (Note: in NSW leads must be elevated off the
                                                                                                         ground and supported by insulated stands).
                                                                     C      3    H      6        Suitable hearing protection is to be worn when             Competent           D     3     M
                                  Exposure to excessive
                                                                                 13               operating power tools.                                     Operator                        9
                                  noise
                                                                     C      4     E     5        Ensure the work area is free of any combustible or         Competent           D     4     H
                                  Sparks (fire & explosion)
                                                                                 18               flammable materials.                                       Operator                        14
                                                                                        4
584 Milton Road TOOWONG QLD 4066                                  SWMS Approved by:    Jamie Gilbert                                                                VERSION 6 – September 2015
P: (07) 3335 5000 F: (07) 3335 5005                               Position: National Health & Safety Co-ordinator                                                                      Page 62
ABN: 52 009 778 330

Used in these records

About this file

File size
16.2 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

WHSMP.pdf · 16.2 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.