SWMS:09 – Working with Bonded Asbestos Containing Materials – N/A
Safe Work Methods
Responsible Residual
H Controls / Work Methods
Person/s for Risk
Job Steps Potential Hazards L C R O 1. Eliminate 2. Substitute 3. Isolate 4. Engineer Monitor & L C R
C 5. Admin 6. PPE Review
Removing bonded ACM. Entry to the work area by the C 3 H 3 Segregate the asbestos work area to restrict entry to Licensed B D 3 M
public – possibly exposing them to 13 authorised persons only by defining the work area Class 9
the risk of inhalation of airborne (erecting barricades and signs to ensure unauthorised Removalist
asbestos fibres. person do not enter the asbestos work area). The
distances and placement of barricades and signs is to be
further risk assessed at the time and location prior to the
work commencing.
5 Signs erected are to comply with AS 1319.
2 Carry out the work with as few people present as possible
and only asbestos removal personnel and / or occupational
hygienists are to be in the asbestos work area.
Contamination of clean surfaces B 2 H 3 Cover any surface within the asbestos work area with Licensed B C 2 M
12 0.2mm plastic sheeting and duct tape to prevent Class 8
contamination of the surface. Removalist
If using a bucket of water, do not re-soak the rags in the
5
bucket (as this will contaminate the water), instead either
fold the rag so a clean surface is exposed or use another
rag.
3 Set up a dry decontamination facility appropriate for the
removal job inside the asbestos work area.
6 Wear disposable overalls and gloves to prevent
contamination to the skin and clothes of removal workers.
Line a waste skip or other waste bin with 0.2mm polythene
plastic and secure it in place.
3
Shut doors, windows and turn off air conditioning units and
systems that affect air in the asbestos work area.
3
Cover up any air conditioning vents, returns or RACs with
3 0.2mm polyethylene plastic using duct tape to ensure dust
does not get into the air conditioning systems.
584 Milton Road TOOWONG QLD 4066 SWMS Developed by: Jamie Gilbert VERSION 8 – September 2015
P: (07) 3335 5000 F: (07) 3335 5005 Position: National Health & Safety Co-ordinator Page 74
ABN: 52 009 778 330
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
WHSMP.pdfRelated documentApplication case desk ↗
About this file
- File size
- 16.2 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.