                                                                            SWMS:18 – A Pre Cast Panel Erection – N/A
Safe Work Methods
                                                                                                                                                        Responsible
                                                                                  H                      Controls / Work Methods                                        Residual Risk
                                                                                                                                                        Person/s for
          Job Steps                    Potential Hazards           L    C    R    O              1. Eliminate 2. Substitute 3. Isolate 4. Engineer       Monitor &       L    C     R
                                                                                  C                               5. Admin 6. PPE                          Review
                                                                   C    4     E    4     Panels are to be designed by an engineer with                Hutchinson       D     4    H
Planning for the work and Pre -   Improper design of panels for
                                                                             18           consideration given to both the loads imposed on the         Builders Site               14
Cast panel design                 erection and in service loads
                                                                                          panels during erection and lifting, as well as when the      Foreman
                                                                                          panels are part of the final structure.
                                                                                         Obtain design engineer drawings for panel design,            Design
                                                                                          drawings for panel erection and engineer sign                Engineer
                                                                                   5
                                                                                          off/certification letter of panel design. The drawings are
                                                                                          to cover items such as:
                                                                                           - Design of the panel itself for the in-situ application
                                                                                               as part of the final structure;
                                                                                           - Design of the panel for lifting and other installation
                                                                                               loads;
                                                                                           - Layout of the panels during construction of the
                                                                                               building or structure with temporary bracing
                                                                                               installed; and
                                                                                           - Layout of the building or structure in its completed
                                                                                               form with temporary bracing removed and
                                                                                               permanent connection detailed.
                                                                   C    4     E    4     Deadmen are to be designed by an engineer and                Hutchinson       D     4    H
                                  Improper design of deadmen
                                                                             18           drawings are to be kept on site outlining the                Builders Site               14
                                                                                          dimensions, concrete strength, steel content and             Foreman
                                                                                          location, terrain category (for wind) and soil type.
                                                                                         Written verification is to be obtained from an engineer      Design
                                                                                   4
                                                                                          outlining that the deadmen are able to resist wind           Engineer
                                                                                          loadings on the panels (in accordance with AS 1170.
Preparation of the deadmen        Falls into excavations / bore    C    4     E    3       Excavations are to be suitably barricaded (1 metre back    Hutchinson       D     4    H
including installation            pier                                       18             from the edge) to restrict access to the area              Builders Site               14
                                                                                           Bore piers are to be back filled (with concrete) as soon   Foreman
                                                                                   4        as possible or place a suitable cover over.



584 Milton Road TOOWONG QLD 4066                             SWMS Developed by:   Jamie Gilbert                                                             VERSION 9 – September 2015
P: (07) 3335 5000 F: (07) 3335 5005                          Position:            National Health & Safety Co-ordinator                                                        Page 20
ABN: 52 009 778 330

Used in these records

About this file

File size
16.2 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

WHSMP.pdf · 16.2 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.