Hutchinson Builders – ABN:52 009 778 330
Work Health & Safety Management Plan
Appendix 8 – Emergency Response Plan
Version: 9.1
In Case of Inclement Weather affecting Hoist Operation
Working 4 levels above Hoist Stop
a. Emergency services enter the Hoist at ground level and are then taken up to the relevant
floor level for operating the Hoist – then,
b. Emergency services walk up the stair well to the relevant floor level where the injured
worker/s is situated then after medical treatment is provided the worker/s is then
stretcher conveyed back down to the Hoist working level, onto the Hoist and down to
awaiting ambulance/s.
In Case of Inclement Weather causing the Crane Only to Stop and Hoist still Operating
To top live Working Deck
c. Notify the Hoist operator of the situation - to dispose of the load and bring the Hoist car
down to the ground floor – to wait for emergency services/fire and rescue to transfer
personnel and equipment up to the live formwork deck – then,
d. After medical treatment is provided the worker/s is then stretcher conveyed back down
to the Hoist working level, onto the Hoist and down to awaiting ambulance/s.
From the Live Deck into Jump cells
e. Emergency services/fire and rescue service from the live deck - access the Jump Forms
cells or main jump deck via the trailing access stairs and hatches until they reach the
injured worker/s where they will provide medical treatment and extraction procedures
required to safety and effectively remove the injured worker/s from the incident scene
back to either the waiting Hoist - and then stretcher conveyed them back down to the
ground floor to the waiting ambulance/s.
The site management team will access the site’s capability on a regular basis, to maintain a functional
emergency access that requires access by emergency services to attend incidents and accidents on site –
refer to the Fire/Emergency Control Structure Procedure.
Page 9 of 26
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
WHSMP.pdfRelated documentApplication case desk ↗
About this file
- File size
- 16.2 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.