GENERAL COMMITTEE MEETING AGENDA 15 JUNE 2020
7088_A04-66 A Block 20 – Elevations prepared by 29.06.2018
Blackburne Jackson Design
7088_A04-70 A Block 21 – Elevations prepared by 29.06.2018
Blackburne Jackson Design
7088_A04-71 A Block 21 – Elevations prepared by 29.06.2018
Blackburne Jackson Design
WD1.3 I Site Plan prepared by Sparks Architects 16-05-2018
WD1.8 I Ground Floor Plan Block 7 prepared by 16-05-2018
Sparks Architects
WD1.11 H Ground Floor Plan Block 8 prepared by 16-05-2018
Sparks Architects
WD1.14 H Ground Floor Plan Block 9 prepared by 16-05-2018
Sparks Architects
Condition 33
33. Carparking shall be provided within the site generally as shown on the approved plans.
Carparking shall include a minimum of:
a. For the Multiple Dwelling Unit component:
i. 224 covered spaces;
ii. 17 uncovered spaces; and
iii. 35 uncovered spaces to be designated through the Principal Community
Management Scheme as Exclusive Use Areas within the common property
and accessible at all times for visitors. These Exclusive Use Areas are to
remain within the common property in perpetuity for the purposes of visitor
carparking and are to be managed by the Principal Body Corporate and
Subsidiary Body Corporates.
b. For the Resort Facilities Building component:
i. A minimum of 30 uncovered spaces are to be designated through the
Principal Community Management Scheme as Exclusive Use Areas, within
the common property, for the Resort Facilities Building. These parking
spaces are to be accessible at all times for patrons and staff of the Resort
Facilities Building.
ii. All 30 patron and staff carparking spaces are to be provided within
proximity of the Resort Facilities Building, that is, not located along the
proposed new road along the eastern property boundary.
iii. All 30 spaces are to be fully constructed and available for use prior to the
commencement of the use of the Resort Facilities Building.
Condition 83
83. The development shall comply with the Noise Management Plan (Report No:
R19084/D3295/Rev.4/30.03.20) prepared by David Moore & Associates and dated 30
March 2020 to the reasonable satisfaction of Council, including:
a. The necessary and appropriate noise control measures incorporated into the
façade of the apartments and within the restaurant/café in the Resort Facilities
Building. These measures shall include:
i. Upgraded glazing and air-conditioning to the potentially affected
apartments;
ii. Strategically placed wing walls on balconies to screen the apartment and
balconies from outdoor dining areas;
Page 12 of 52