The fence is to be constructed on top of the proposed retaining wall. Internal Courtyard
fences are also to be made of non-combustible materials. Please refer to typical Bushfire
Management schematic plan and section for locations.
5.3 Construct dwellings to meet the requirements of AS3959:2009
Dwellings will be required to be constructed to AS3959:2009 Construction of Buildings in
Bushfire Prone Areas. Unit blocks B, C and D (inclusive of all individual townhouses) will be
required to be constructed to Bushfire Attack Level – Flame Zone. Unit block A will be
required to be constructed to Bushfire Attack Level 12.5.
The drawings prepared by Reitsma exhibit appropriate building materials and notation to
allow future compliance with BAL FZ and BAL 12.5 respectively. Full compliance assessment
with these construction requirements will need to be undertaken at Building Works Stage by
a suitably qualified Building Certifier. Building elements situated less than 10m from the
unmanaged vegetation are required to satisfy the testing criteria of Australian Standard
AS1530.2 Methods for fire tests on building materials, components and structures.
Metal bushfire shutters may need to be installed over windows facing the bushland in the
absence of suitably rated bushfire resistant windows being able to be installed.
A property rate card notation should be included on the allotment stating that building works
on the allotment will be required to comply with AS3959:2009 Construction of Buildings in
Bushfire Prone Areas or subsequent editions.
5.4 Undertake appropriate landscaping on the site to minimise the effects of wildfire.
Fuels that can contribute to the spread and behaviour of fires in the Bushland Urban
interface (I-zone) include: private gardens (trees, shrubs, lawns, mulches), external
structures (houses, garages, sheds, lean-to’s, fences), general lifestyle detritus (rubbish,
wood piles, compost heaps, things that will be used one day), and public spaces (green
spaces, access ways, roadside verges) (Ellis and Sullivan 2004).
Ellis and Sullivan 2004 estimate the radiant heat flux emanating from burning mulch to be
between 5kW/m2 and 30kW/m2. In this regard burning mulch has the potential to break
windows and make areas indefensible. Mulches can be blown by the wind accompanying
bushfires and ‘rolled up’ resulting in intense flaming and burning particles that deposited
against the facades of buildings.
In this regard landscaping must be designed to not include materials and species that are
highly combustible and avoid placing combustible materials adjacent building elements which
may in turn cause combustion of the buildings.
The following are to be observed in the design of site landscaping:
No trees or shrubs greater than 5m tall are to be proposed such that the outer edge of
the mature specimen is within 5m of any window of any building. Trees may be planted
adjacent concrete tilt up party walls due to the fire rating level of these walls provided
that they are also not adjacent glazing elements. Trees should not be planted in
continuous rows;
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Development Application part 2 Report/Plans - MCU11/0254Related documentApplication case desk ↗
About this file
- File size
- 41.8 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.