JOB NUMBER 15/1054 SITE CLASSIFICATION REPORT
CLIENT ZIGANNAIRE PTY LTD
SITE LOCATION PROPOSED DUPLEX,
61 ELANDA STREET, SUNSHINE BEACH
REPORT DATE 21/10/2015
1. INTRODUCTION
The purpose of this report is to classify the subject allotment in accordance with Australian Standard
2870 - 2011 'Residential Slabs and Footings'. From this classification a footing system can be
recommended for the structure so as to allow adequate performance of the footings under the soil
conditions determined at the site.
Trees: There are several small to large trees on and adjacent to the proposed site. Global
Testing recommends an experienced arborist be commissioned to quantify the existing size,
location, predicted maximum height and type of these trees to aid in the design process. It is the
responsibility of the designing engineer to apply the principals of AS2870-2011 Appendix H
"Guide to Design of Footings for Trees". The classification herein excludes the effect of trees on
the site.
Please note: The site has an existing residence which is to be removed.
2. SITE DESCRIPTION
Type of Allotment Residential
Vegetation (Building Envelope) Grassed/Scattered small to large sized
mature trees
Vegetation (Allotment) Grassed/Scattered small to large sized
mature trees
Road Status Sealed
Slope 7-9% to the Rear
Surface Water will Drain Towards Rear
Will Surface water from adjoining May
allotments traverse this site
Does the site have any watercourses No
Surrounding Allotments
Left Existing Residence
Right Existing Residence
Rear Existing Residence
Depth to Weathered Rock N/a
Depth to Water Table N/a
3. SITE CLASSIFICATION AND TARGET STRATA
Based on the findings of the site investigation, the classification of the site is considered to
conform to:-
CLASS “ P ” (Due to poor bearing capacity, the presence of trees and
the removal of an existing residence - Piering Required)
(PLEASE NOTE: If not for the poor bearing capacity and trees encountered and the removal of an
existing residence, this site would have the characteristics of an 'S' site)
in accordance with Australian Standard 2870 - 2011, 'Residential Slabs and Footings,
Construction'.
15/1054 Page 1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Tod Consulting Stormwater Plans v2.pdfRelated documentApplication case desk ↗
About this file
- File size
- 6.7 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.