The target stratum for the foundation of the structure at location BH1 is the SAND at a
depth of 800mm below existing ground level.
The target stratum for the foundation of the structure at location BH2 is the SAND at a
depth of 1300mm below existing ground level.
It is the designing engineers responsibility to address the potential influence of any trees
present on or around the proposed building site.
If any fill is placed over the existing ground, the structure shall be piered through the fill
into the existing material. Further note that the placement of reactive material as fill, or cutting
of the site may change the site’s classification.
4. SOIL PROFILE
Refer to Soil Profile Report for borelog information
Whilst every effort has been made to ensure that the borelogs carried out at the subject
allotment are indicative of the soil profile over the site any discrepancy between the profile
detailed in the borelogs and that observed during construction shall be referred to Global
Testing for immediate attention.
5. MATERIALS LABORATORY TEST RESULTS
Soil Laboratory testing was not carried out on samples of the soil taken from the site because the clay
content of the material was too low for Shrink-Swell movements to be critical in the classification of
the soil profile. Determination of the classification for the site in this situation is based upon results
from Dynamic Cone Penetrometer testing performed over the site.
BOREHOLE n/a
DEPTH RANGE OF SAMPLE n/a
LIQUID LIMIT n/a
PLASTIC LIMIT n/a
PLASTIC INDEX n/a
LINEAR SHRINKAGE n/a
INSTABILITY INDEX n/a
SHRINK SWELL INDEX,Iss n/a
PREDICTED SURFACE MOVEMENT n/a
Please note that the Plasticity Index (PI) determined by the Atterberg Test may be correlated to an
Instability Index (Ips)with reference to the results of extensive testing carried out by others, notably,
Dr P Mitchell, ‘Footings for Small Scale Domestic Structures, ’March 1990.
Yours Sincerely,
MICHAEL PINKNEY. (Laboratory Manager)
15/1054 Page 2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Tod Consulting Stormwater Plans v2.pdfRelated documentApplication case desk ↗
About this file
- File size
- 6.7 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.