                                           Environmental EME Report
                                 Cooran, 244 Tablelands Road, COORAN QLD 4569

       This report provides a summary of Calculated RF EME Levels around the wireless base station

Date 25/5/2018                                                                                  RFNSA Site No. 4569003
Introduction
The purpose of this report is to provide calculations of EME levels from the existing facilities at the site and any proposed
additional facilities.
This report provides a summary of levels of radiofrequency (RF) electromagnetic energy (EME) around the wireless base
station at Cooran, 244 Tablelands Road COORAN QLD 4569. These levels have been calculated by Ericsson using
methodology developed by the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA).
The maximum EME level calculated for the proposed systems at this site is 0.31% of the public exposure limit.

The ARPANSA Standard
ARPANSA, an Australian Government agency in the Health and Ageing portfolio, has established a Radiation Protection
Standard specifying limits for general public exposure to RF transmissions at frequencies used by wireless base stations. The
Australian Communications and Media Authority (ACMA) mandates the exposure limits of the ARPANSA Standard.

How the EME is calculated in this report
The procedure used for these calculations is documented in the ARPANSA Technical Report “Radio Frequency EME Exposure
Levels - Prediction Methodologies” which is available at http://www.arpansa.gov.au.
RF EME values are calculated at 1.5m above ground at various distances from the base station, assuming level ground.
The estimate is based on worst-case scenario, including:
    • wireless base station transmitters for mobile and broadband data operating at maximum power
    • simultaneous telephone calls and data transmission
    • an unobstructed line of sight view to the antennas.
In practice, exposures are usually lower because:
     • the presence of buildings, trees and other features of the environment reduces signal strength
     • the base station automatically adjusts transmit power to the minimum required.
Maximum EME levels are estimated in 360° circular bands out to 500m from the base station.
These levels are cumulative and take into account emissions from all wireless base station antennas at this site.
The EME levels are presented in three different units:
      •     volts per metre (V/m) – the electric field component of the RF wave
      •     milliwatts per square metre (mW/m²) – the power density (or rate of flow of RF energy per unit area)
      •     percentage (%) of the ARPANSA Standard public exposure limit (the public exposure limit = 100%).

Results
The maximum EME level calculated for the proposed systems at this site is 3.44 V/m; equivalent to 31.42 mW/m² or 0.31% of
the public exposure limit.




Environmental EME report (v11.4, Oct 2016)                                        Produced with RF-Map 2.0 (Build 5.0) NAD (v1.0.85808.28892)
Log in to download the original file

Cooran - Development Application.pdf · 12.7 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.