Original source · versioned page text
Cooran - Development Application
Attached to the e-mail Service & Utility Type 3 Tower (Telecommunications) -MCU18/0166.
The original of this document is very large (12.7 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Radio Systems at the Site
There are currently no existing radio systems for this site.
It is proposed that this base station will have equipment for transmitting the following services:
Carrier Radio Systems
NBN Co LTE2300 (proposed)
Calculated EME Levels
This table provides calculations of RF EME at different distances from the base station for emissions from existing equipment
alone and for emissions from existing equipment and proposed equipment combined.
Maximum Cumulative EME Level at 1.5m above ground – all carriers at this site
Distance from the antennas at
Existing Equipment Proposed Equipment
Cooran, 244 Tablelands Road
in 360° circular bands Electric Field Power Density % ARPANSA Electric Field Power Density % ARPANSA
V/m mW/m² exposure limits V/m mW/m² exposure limits
0m to 50m 0.91 2.22 0.022%
50m to 100m 0.84 1.87 0.019%
100m to 200m 3.44 31.42 0.31%
200m to 300m 3.35 29.76 0.3%
300m to 400m 2.18 12.57 0.13%
400m to 500m 1.61 6.84 0.068%
3.44 31.42 0.31
Maximum EME level 187.019 m from the antennas at Cooran, 244
Tablelands Road
Calculated EME levels at other areas of interest
This table contains calculations of the maximum EME levels at selected areas of interest that have been identified through the
consultation requirements of the Communications Alliance Ltd Deployment Code C564:2011 or via any other means. The
calculations are performed over the indicated height range and include all existing and any proposed radio systems for this site.
Maximum Cumulative EME Level
Height / Scan All Carriers at this site
Additional Locations relative to location Existing and Proposed Equipment
ground level
Electric Field Power Density % of ARPANSA
V/m mW/m² exposure limits
1 Residence 1 on Tablelands Rd, Cooran 0m to 3m 0.079 0.017 0.00017%
2 Residence 2 on Tablelands Rd, Cooran 0m to 3m 0.53 0.74 0.0074%
3 Residence 1 on Akubra Lane, Cooran 0m to 3m 0.94 2.37 0.024%
4 Residence 1 on Brewers Rd, Cooran 0m to 3m 0.81 1.74 0.017%
Environmental EME report (v11.4, Oct 2016) Produced with RF-Map 2.0 (Build 5.0) NAD (v1.0.85808.28892)
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.