Original source · versioned page text
Appendix G - Bushfire Hazard Assessment
Attached to the e-mail MCU17/0551 - Information Response - 20 Trading Post Rd Cooroy.
19 & 20 Trading Post Road Cooroy QLD March 2018 Bushfire Hazard Assessment Report 2.1 ASSESSMENT PER SPP Potential Fireline Intensity (Equation 1) per SPP 2016 Technical Manual Equation 1. PFI = 0.62 PFL2 *FFDI*EXP (0.069 *slope degrees) PFI Potential Fireline Intensity PFL Potential Fuel Load per Redi-Portal data FFDI 20 year FFDI site specific 47 Area 1 VHC 41.4 Low grass or tree cover in built up areas VHC 41.4 Potential Fuel Load 3t/ha Slope Degrees 20 Equation 1. PFI = 0.62 x3 2 * 47* EXP (0.069 *2) = PFI 301 kW/m Low Hazard range (0-4,000 kW/m) Area 2 VHC 8.1 Wet eucalypt tall open forest VHC 8.1 Potential Fuel Load 28.9t/ha (weighted PFL per Redi-portal data) Slope Degrees, maximum slope 10 Equation 1. PFI = 0.62 x 28.92 * 47* EXP (0.069 * 1) = PFI 26,077 kW/m High Hazard range (20,000- 40,000 kW/m) Area 3 VHC 40.4 Potential Fuel Load 5 t/ha Slope Degrees, maximum slope 10 (flat grade to upslope, slope not contributing to hazard) Equation 1. PFI = 0.62 x 52 * 47* EXP (0.069 * 1) = PFI 781 kW/m Low Hazard range (0 -4,000 kW/m) 9 Page Brisbane Bushfire Consulting Pty. Ltd. Bushfire Consultant, Architect BOAQ ARBV P.O. Box 219, Point Lookout Qld 4183 [email protected] brisbanebushfire.com.au Mob 0490 494 111