Council archive · source document
SUPERSEDED - Compiled Approved Plans - 51983.3225.22 (As Published)
Plans and drawings: the text below has words only, no drawings.
NOOSA COUNCIL
APPROVED PLAN
51983.3225.22 19 MAY 2025
[OCR of page images]
NOTE NOTES NOTE:
UNLESS NOTED OTHERWISE, ALL EXISTING 1. ALL CONSTRUCTION WORK UNDERTAKEN THESE DRAWINGS ARE DESIGN CONCEPTS
BUILT WORKS ARE TO REMAIN. FOR FURTHER IS TO COMPLY WITH THE NATIONAL ONLY AND SHALL NOT BE USED IN ANY
CLARIFICATION ON EXTENT OF DEMOLITION CONSTRUCTION CODE (BCA), RELEVANT WAY FOR STRUCTURAL PURPOSES. REFER
WORKS, REFER TO PROPOSED FLOOR PLAN FOR AUSTRALIAN STANDARDS AND TO STRUCTURAL ENGINEER'S DETAILS
PROPOSED RECONFIGURATION LAYOUT, WALL APPLICABLE LOCAL AUTHORITY FOR ALL MEMBER SIZES, SPECIFICATIONS
SETOUT DIMENSIONS AND OPENING LOCATIONS. REQUIREMENTS. AND SITE SPECIFIC STRUCTURAL
2. ALL SETBACK/SETOUT DIMENSIONS ARE REQUIREMENTS.
(BY TO BE CHECKED AND VERIFIED ON SITE
(22087 4 (3097 PRIOR TO CONSTRUCTION.
Vv
NOTE:
ROOM DIMENSIONS
N\ SHOWN ARE TO
ADJOINING ADJOINING FINISHED WALL FACES.
VILLA VILLA | ° _
ROADWAY
4
q
ADJOINING
a __ BOUNDARY _ VILLA LEGEND
| AW AWNING WINDOW
COL STEEL COLUMN
CT COOKTOP
DHW DOUBLE HUNG WINDOW
DP DOWNPIPE
DRY CLOTHES DRYER
FW FLOOR WASTE
DW DISHWASHER
fr~™ FGW FIXED GLASS WINDOW
HB HAND BASIN
\ 4300 LVW LOUVRE WINDOW
OV OVEN
\
| 70295 7013860, 79 p80 70 174gh —78- —
mt att at at
PANTRY
| 1950x1360mm
TIMBER
BOUNDARY
70
(DEDICATED LOT
EXCLUSIVE USE AREA)
945
7
715
7450, 920 60020
7
BOUNDARY
as
ca
Q
X\ P PANTRY
€ 600mm WIDE 'HEKA HOOD' OR APPROVED REF REFRIGERATOR
EQUIVALENT WINDOW AWNINGS x2. BUILDER SGD SLIDING GLASS DOOR
& TO CONFIRM SPECIFIC AWNING DETAILS WITH SGW SLIDING GLASS WINDOW
04521 FGW
—<¢
BOUNDARY
1785
CLIENT PRIOR TO CONSTRUCTION SHR SHOWER
SWP SANITARY WASTE PIPE
wc TOILET
WM WASHING MACHINE
WP WASTE PIPE
3295
1520
2115 DHW
7
70
be
al
t
LX
Zz SS
DECK
4895x2110mm
— TIMBER
BOUNDARY.
2120
ROOF OVER
OVER
7
“ ADJOINING
_ Jf SHARED
ADJOINING ROADWAY
SHARED BOUNDARY
ROADWAY (DEDICATED LOT N\
EXCLUSIVE USE AREA)
70 CRITICAL NOTE: LIFT SHAFT OPENING AND
EXTENTS CRITICAL TO SUIT LIFT SUPPLIER'S
4845 ROOF OVER 1741
é aa 0 A REQUIREMENTS. BUILDER TO CONFIRM SHAFT
OPENING ON SITE AND COORDINATE WITH LIFT
SUPPLIER TO ENSURE SUFFICIENT OPENING.
R
COL
FRAMING SIZING AND STRUCTURAL REQUIREMENTS THROUGHOUT PROPOSED
NOOSA COUNCIL WORKS. WHERE 90mm STUD FRAMES ARE REQUIRED TO SUIT PROPOSED
STRUCTURE, BUILDER TO MAINTAIN EXTERNAL BUILDING FOOTPRINT AND ADJUST
APPROVED PLAN (01 PROPOSED FLOOR PLAN - LEVEL | ROOM SIZES ACCORDINGLY ON INTERNAL SIDE, ENSURING MINIMUM INTERNAL
51983.3225.22 19 MAY 2025 , SCALE 1-100 CIRCULATION WIDTHS ARE MAINTAINED (WHERE REQUIRED). ALL DIMENSIONS
SHOWN ARE FOR APPROVAL PURPOSES ONLY, STRUCTURAL LAYOUT TO BE
CONFIRMED ON SITE BY PROJECT ENGINEER & BUILDER PRIOR TO CONSTRUCTION.
> CRITICAL NOTE: PARTITION WALLS SHOWN ARE BASED ON 70mm WIDE STUD FOR
4 (B APPROVAL PURPOSES ONLY. REFER TO STRUCTURAL ENGINEER'S DETAILS FOR ALL
NOTES: AMENDMENTS PROJECT DRAWING CREATED SCALE @AB
41, THIS IS A COMPUTER GENERATED DRAWING, DO NOT AMEND BYHAND.| Rey DATE —_DESCRIPTION BY FOR APPROVAL
2. THIS DRAWING SHOWS DESIGN INTENT ONLY. ALL DIMENSIONS AND AUG 2023 11
SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO CONSTRUCTION. | A 17.08.2023] ISSUE FOR BUILDING APPROVAL cB PROPOSED RESIDENTIAL ALTERATIONS AUG 202300 11000
3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS | 8 | 14.01.2025] PROJECT SCOPE ADJUSTMENTS 6a ‘ADDRESS PROJECTNO. REVISION www.gtgroup.net.au
ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION, © | 15.01.2025) UPDATED PROJECT SCOPE ADJUSTMENTS GB 22048 c RUG Es [lt NES
4, DONO SOA PS ORANG 2/30 HASTINGS STREET, NOOSA HEADS QLD 4567 a Re et eee
cr GROUP BULOING DESIGN, THESE DRAWINGS ARE PROTECTED BY | ASTOR: 8 DRAWING “n REO
lL | ORGNAL SES; SEE
THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED | ORIGINAL SHEET SIZE: A3 (420x297) PROPOSED FLOOR PLAN - LEVEL 1 A101 Oe
WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED - Compiled Approved Plans - 51983.3225.22 (As Published)Related documentApplication case desk ↗
About this file
- File size
- 7.7 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.