Council archive · source document
SUPERSEDED - Compiled Approved Plans - 51983.3225.22 (As Published)
Plans and drawings: the text below has words only, no drawings.
NOOSA COUNCIL
APPROVED PLAN
51983.3225.22 19 MAY 2025
[OCR of page images]
ADJOINING
VILLA
ROADWAY
>
ADJOINING
VILLA
BOUNDARY
®
704995 70 4999 70 70
2500
90
4
q
BOUNDARY,
ADJOINING
SHARED
ROADWAY
NOOSA COUNCIL
APPROVED PLAN
51983.3225.22 19 MAY 2025
1725x900mm
TILE
EXTG.
DP “COL
(EXTG,) (EXTG,)
I} STORE
ADJOINING
VILLA
0615 SGW
@—_
!
a
i
HANDRA|
BOUNDARY _
(DEDICATED LOT
EXCLUSIVE USE AREA)
70
130
a
3210
a
2100
7
&@
70
990 yp
Al
BOUNDARY
(DEDICATED LOT
EXCLUSIVE USE AREA)
NOTE
UNLESS NOTED OTHERWISE, ALL EXISTING
BUILT WORKS ARE TO REMAIN. FOR FURTHER
CLARIFICATION ON EXTENT OF DEMOLITION
WORKS, REFER TO PROPOSED FLOOR PLAN FOR
PROPOSED RECONFIGURATION LAYOUT, WALL
SETOUT DIMENSIONS AND OPENING LOCATIONS.
70
a
©
70
920
y
NOTE: ALTERATIONS TO EXISTING
STRUCTURAL FRAMING TO SUIT
ADJUSTED STAIR CONFIGURATION TO
STRUCTURAL ENGINEER'S DETAILS
1765
70
BOUNDARY
2500
“ ADJOINING
SHARED
ROADWAY
A
CRITICAL NOTE: LIFT SHAFT OPENING AND
EXTENTS CRITICAL TO SUIT LIFT SUPPLIER'S
REQUIREMENTS. BUILDER TO CONFIRM SHAFT
OPENING ON SITE AND COORDINATE WITH LIFT
SUPPLIER TO ENSURE SUFFICIENT OPENING.
(01. \ PROPOSED FLOOR PLAN - GROUND
Yo) SCALE 1:100
NOTES
1. ALL CONSTRUCTION WORK UNDERTAKEN
|S TO COMPLY WITH THE NATIONAL
CONSTRUCTION CODE (BCA), RELEVANT
AUSTRALIAN STANDARDS AND
APPLICABLE LOCAL AUTHORITY
REQUIREMENTS.
2, ALL SETBACK/SETOUT DIMENSIONS ARE
TO BE CHECKED AND VERIFIED ON SITE
PRIOR TO CONSTRUCTION.
AN
AS
NOTE:
THESE DRAWINGS ARE DESIGN CONCEPTS
ONLY AND SHALL NOT BE USED IN ANY
WAY FOR STRUCTURAL PURPOSES. REFER
TO STRUCTURAL ENGINEER'S DETAILS
FOR ALL MEMBER SIZES, SPECIFICATIONS
AND SITE SPECIFIC STRUCTURAL
REQUIREMENTS.
NOTE:
ROOM DIMENSIONS
SHOWN ARE TO
FINISHED WALL FACES.
LEGEND
AW
COL
cT
DHW
DP
DRY
FW
DW
FGw
HB
HWU
AWNING WINDOW
STEEL COLUMN
COOKTOP
DOUBLE HUNG WINDOW
DOWNPIPE
CLOTHES DRYER
FLOOR WASTE
DISHWASHER
FIXED GLASS WINDOW
HAND BASIN
HOT WATER UNIT
LVW LOUVRE WINDOW
OV OVEN
P PANTRY
REF REFRIGERATOR
SGD SLIDING GLASS DOOR
SGW_ SLIDING GLASS WINDOW
SHR SHOWER
SWP SANITARY WASTE PIPE
we TOILET
WM WASHING MACHINE
WP WASTE PIPE
CRITICAL NOTE: PARTITION WALLS SHOWN ARE BASED ON 70mm WIDE STUD FOR
APPROVAL PURPOSES ONLY. REFER TO STRUCTURAL ENGINEER'S DETAILS FOR ALL
FRAMING SIZING AND STRUCTURAL REQUIREMENTS THROUGHOUT PROPOSED
WORKS. WHERE 90mm STUD FRAMES ARE REQUIRED TO SUIT PROPOSED
STRUCTURE, BUILDER TO MAINTAIN EXTERNAL BUILDING FOOTPRINT AND ADJUST
ROOM SIZES ACCORDINGLY ON INTERNAL SIDE, ENSURING MINIMUM INTERNAL
CIRCULATION WIDTHS ARE MAINTAINED (WHERE REQUIRED). ALL DIMENSIONS
SHOWN ARE FOR APPROVAL PURPOSES ONLY, STRUCTURAL LAYOUT TO BE
CONFIRMED ON SITE BY PROJECT ENGINEER & BUILDER PRIOR TO CONSTRUCTION.
NOTES:
4, THIS IS A COMPUTER GENERATED DRAWING. DO NOT AMEND BY HAND.
2. THIS DRAWING SHOWS DESIGN INTENT ONLY. ALL DIMENSIONS AND
AMENDMENTS
REV
DATE
DESCRIPTION By
FOR APPROVAL
PROJECT
DRAWING CREATED SCALE @A3
PROPOSED RESIDENTIAL ALTERATIONS
ADDRESS
2/30 HASTINGS STREET, NOOSA HEADS QLD 4567
DRAWING
PROPOSED FLOOR PLAN - GROUND
AUG 2023 1:100
PROJECT NO, REVISION
22048 D
DWG. NO.
A100
17.08.2023
13.09.2023
14.01.2025
15.01.2025
ISSUE FOR BUILDING APPROVAL. GB
UPDATED ISSUE FOR BUILDING APPROVAL
PROJECT SCOPE ADJUSTMENTS
UPDATED PROJECT SCOPE ADJUSTMENTS.
‘SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO CONSTRUCTION. A
3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS B
ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION. c
4. DO NOT SCALE THIS DRAWING. D
COPYRIGHT:
© GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY
www.gtgroup.net.qau
[email protected]
ere RPP
(07) 3298 6938
GT GROUP
[Auton Ge
| ORIGINAL SHEET SIZE: A3 [420x297mm)
D
THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED
WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED - Compiled Approved Plans - 51983.3225.22 (As Published)Related documentApplication case desk ↗
About this file
- File size
- 7.7 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.