RFI - App D - Liveit RFI Response · 132008.299.02
Reference #70250009-ENAC-LTR01-R1
iv. The assessment of patron noise has been provided for the LAeq parameter only, include
assessment of the LAmax parameter also for outdoor areas that will be used in the 10pm
to 7am time period.
v. Justify the patron numbers used in the assessment as Table 7 indicates only 18 persons
spread over three outdoor areas whereas the proposal is for 48 persons. Provide revised
assessment with more realistic patron numbers in outdoor areas.
Our Response:
Meteorological data used to identify and exclude weather affected periods was obtained from the
Bureau of Meteorology (BOM) Tewantin Weather Station, being the nearest representative station
to the subject site.
Item 8 (i)
The noise logger was installed at a height of approximately 1.5 metres above ground level and
positioned to minimise the influence of reflective surfaces. The monitoring location is considered
generally representative of free-field conditions in accordance with AS1055:2018.
Item 8 (ii)
The revised Noise Impact Assessment includes a sleep disturbance assessment for relevant
night-time maximum noise events. Specifically, LAmax screening has been undertaken for:
• Car door closure events within the on-site car park; and
• Patron activity associated with the kitchen-adjoining area.
These sources represent the only applicable night-time maximum noise events associated with
the development.
Item 8 (iii)
Time-varying sources (e.g. patrons, intermittent car park activity) and continuous sources
(mechanical plant) have been assessed separately because they are characterised differently.
Mechanical plant is assessed as a continuous source against a background referenced criterion
(i.e. RBL + 0 dB limit), which is inherently conservative because it requires plant to remain
effectively at or below the prevailing background noise level to avoid intrusive impacts.
In contrast, patron activity and vehicle movements are intermittent and transient in nature. These
sources do not necessary operate continuously over the full assessment period and are more
appropriately assessed using background + 5 dB LAeq criteria.
Live It Acoustics Page 3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
RFI - App D - Liveit RFI Response.pdfRelated documentApplication case desk ↗
About this file
- File size
- 184 KB (small file)
- File type
No other editions are linked here.