RFI - App D - Liveit RFI Response · 132008.299.02

of 7

Text shows just the words. Original shows the document exactly as it was published.

                                                                Reference #70250009-ENAC-LTR01-R1




Item 7

Council Comment:

Clarify how the ambient noise data obtained by the noise logger on the site was adjusted for
extraneous noise and as to whether this included insect noise and whether the measurement
equipment included a frequency analyser to permit assessment of insect noise contribution.

Our Response:

Unattended noise monitoring was undertaken using a Rion NL‑42 Class 2 sound level meter in
accordance with AS1055:2018. Periods affected by adverse meteorological conditions (wind
speeds > 5 m/s or rainfall > 0.3 mm/hr) were excluded. The logger recorded broadband
A‑weighted statistical descriptors only; one-third octave logging was not undertaken.

The dataset was reviewed graphically to identify anomalous events and potential insect-related
contributions. Periods not considered representative of the prevailing ambient environment were
manually excluded prior to deterring the Rating Background Levels (RBLs).

The adopted RBLs of 37 dBA (day), 35 dBA (evening) and 29 dBA (night) confirm a low ambient
environment. The measured night-time levels in particular do not indicate insect dominant
conditions that would influence the RBLs. Accordingly, frequency analysis was not required.




Item 8

Council Comment:

Clarify/provide the source and meteorological data used to exclude weather affected noise
measurements.

   i.    Clarify the location of the noise logger with respect to the adjacent concrete wall and
         whether the equipment location was free field.
  ii.    In respect to noise criteria, include assessment in respect to Sleep Disturbance and the
         LAmax parameter.
  iii.   Provide assessment of the cumulative noise impact of the development in regard to both
         time varying noise and continuous noise.




Live It Acoustics                                                                          Page 2

Used in these records

About this file

File size
184 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

RFI - App D - Liveit RFI Response.pdf · 184 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.